658689
25
Zoom out
Zoom in
Previous page
1/52
Next page
| 23
Software setup | Zeus Glass Helm Installation Manual
Depth o set
This is a value that can be entered on the
Echo Installation page to make depth
readings relate to any point from the water
surface, to the deepest point of the vessel.
This value is applied to a sonar source
connected via ethernet, and changes will be seen on all devices connected to the network.
Below are some typical ways in which the o set is used:
A) For Depth below Keel: Set the distance from transducer to the bottom of the keel - this
should be set as a negative value.
B) For Depth Below Transducer: no o set required.
C) For Depth Below Surface (waterline): Set the distance from transducer to the surface - this
should be set as a positive value.
AB C
Echosounder software version
For external sounder modules, the software version is displayed in the header of the Echo
Installation dialogue. To upgrade Sonar software, see “NMEA 2000 and Ethernet device
upgrades on page 39.
Water speed calibration (echosounder transducer)
Water speed calibration is used to adjust the speed value from the paddle wheel to match the
actual boat speed through the water. Actual speed can be determined from GPS speed over
ground (SOG) or by timing the boat over a known distance. Water speed calibration should be
performed in calm conditions, with minimal wind and current movement.
Increase this value above 100 % if the paddle wheel is under reading, and decrease this value
if it is overreading, e.g. if the average water speed reads 8.5 knots and SOG records 10 knots
the calibration value needs to be increased to 117 %. To calculate the adjustment, divide the
SOG by the paddlewheel speed, and multiply the product by 100.
Calibration range: 50-200 %. Default is 100 %.
Water speed averaging (echosounder transducer)
Averages water speed by measuring your speed at a selected interval of time. Water speed
intervals range from one to thirty seconds, e.g. if you select  ve seconds, your displayed water
speed will be based on averaging over 5 seconds of sampling.
Calibration range: 1-30 seconds. Default is 1 second.
Water temperature calibration (echosounder transducer)
Temperature calibration is used to adjust the water temperature value from the echosounder
transducer to match the data from another temperature sensor. It may be required to correct
for localised in uences to the measured temperature.
Calibration range: -9.9° - +9.9°. Default is 0°.
Note: Water temperature calibration only appears if the transducer is temperature capable.
Check transducer type selection if this option should be available.
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for BandG Zeus2 Glass Helm at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of BandG Zeus2 Glass Helm in the language / languages: English as an attachment in your email.

The manual is 6,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of BandG Zeus2 Glass Helm

BandG Zeus2 Glass Helm User Manual - English - 136 pages

BandG Zeus2 Glass Helm User Manual - German - 115 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info