Power the NMEA 2000 network
A NMEA 2000 network requires its own 12 V DC power supply protected by a 5 amp fuse or
breaker. For 24 V systems, use a DC-DC converter to supply 12 V
Connect power at any location in the backbone for smaller systems.
For larger systems introduce power at central point in the backbone to “balance” the voltage
drop of the network.
Note: If joining to an existing NMEA 2000 network or similar CAN bus network that already
has it’s own power supply, do not make another power connection.
Note: Do not connect the NMEA 2000 power cable to the same terminals as the start batter-
ies, Autopilot Computer, Radar, thruster or other high current devices.
The drawing below demonstrates a typical small network. The backbone is entirely made up
of T-piece joiners, which are terminated at each end.
12 V DC
T T
-
+
T
Micro-C
Power
Terminator
In the larger system below, the backbone is extended by cable and is also daisy chained
through Triton displays.
+
_
12 V DC
T
T
1
5
4
3
2
6
1 NMEA 2000 power source. Stable 12 V DC only
2 5 Amp fuse or breaker
3 Switch
4 Power cable
5 Micro-C T-joiners
6 NMEA 2000 GPS antenna
7 NMEA 2000 backbone daisy chained using instruments with two ports.
8 NMEA 2000 Micro-C backbone
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for BandG Zeus Touch at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of BandG Zeus Touch in the language / languages: English as an attachment in your email.

The manual is 10,97 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of BandG Zeus Touch

BandG Zeus Touch User Manual - English - 115 pages

BandG Zeus Touch User Manual - German - 115 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info