97
NMEA0183 Conguration
Details the NMEA0183 interfaces. Including CAN Channel, Device ID and Port settings used.
Installing NMEA0183 Input...
NMEA0183 In : Channel : 1, Device : 4, Port: 1, Baud: 4800
Installing NMEA0183 Output...
NMEA0183 Out : Channel : 1, Device : 4, Port: 1, Baud: 4800
Loadcell Conguration
Details of serial Loadcell inputs. Including CAN Channel, Device ID and Port settings used.
LOADCELL Channel : 1, Device : 5, Port: 1, Baud: 4800
Fast Output Conguration (fastout.d)
Details of the output conguration of the [optional] fast output function. Including CAN Channel, Device ID and
Port settings used.
FASTOUT Channel : 1, Device : 6, Port: 1, Baud: 57600
File Consistency Checks
On boot the system checks the consistency of les called in conguration les (e.g. sample.d) with the existence
of the les on the unit. The example warnings below indicate two les are referenced in a le but do not
physically exist:
Loading Sample.d.........
Warning: QFileSystemWatcher: failed to add paths: wtp_default/lters/vmg.l
Warning: QFileSystemWatcher: failed to add paths: wtp_default/lters/vmc.l
Sampler: Loaded Sample File
Sampler: Initialised derived variables
This may be due to the le not being present, the lename being misspelt or the use of uppercase characters in
the conguration les – the operating system automatically renames all lenames to lowercase.
Datalog Task Start
Simple comment to indicate if the datalog task has started (also see Datalog Status, below)
Data logger Running
Alarm Task Start
Simple comment to indicate if the alarm handler task has started
Alarm Manager Running