784763
13
Zoom out
Zoom in
Previous page
1/28
Next page
Manufactured under one or more of these patents.
U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2, Canadian Patent: 2342614,
Australian patent: 2373248 other patents both foreign and domesc applied for and pending. All material copyright of Balboa Water Group.
42281_A | Compable with SpaTouch 1 & 2 13 03.17
Spa Behavior
Pumps
On the Spa Screen, select a “Jets” button once to turn the
pump on or off, and to shift between low- and high-speeds
if equipped. If left running, the pump will turn off after a
time-out period.
Non-Circ Systems
The low-speed of pump 1 runs when the blower or any other
pump is on. If the spa is in Ready Mode (See page 11), Pump 1
low may also activate for at least 1 minute every 30 minutes
to detect the spa temperature (polling) and then to heat
to the set temperature if needed. When the low-speed turns
on automatically, it cannot be deactivated from the panel,
however the high speed may be started.
Circulation Pump Modes
If the system is equipped with a circ pump, it will be
configured to work in one of three different ways:
1. The circ pump operates continuously (24 hours) with the
exception of turning off for 30 minutes at a time when
the water temperature reaches 3°F (1.5°C) above the set
temperature (most likely to happen in very hot climates).
2. The circ pump stays on continuously, regardless of water
temperature.
3. A programmable circ pump will come on when the system
is checking temperature (polling), during filter cycles,
during freeze conditions, or when another pump is on.
The specific Circulation Mode that is used has been
determined by the Manufacturer and cannot be changed
in the field.
Other device options may be available, like Blower, Light,
Mister, etc.
Filtration and Ozone
On non-circ systems, Pump 1 low and the ozone genera-
tor will run during filtration. On circ systems, the ozone
will generally run with the circ pump, but can be limited to
filtration cycles. (On some circs systems, Pump 1 low will run
along with the circ Pump during filtration.)
The system is factory-programmed with one filter cycle that
will run in the evening (assuming the time-of-day is prop-
erly set) when energy rates are often lower. The filter time
and duration are programmable. A second filter cycle can be
enabled as needed.
At the start of each filter cycle, the water devices like
blower, mister device (if these exist) and other pumps will
run briefly to purge the plumbing to maintain good water
quality.
Freeze Protection
If the temperature sensors within the heater detect a low
enough temperature, then the water devices automatically
activate to provide freeze protection. The water devices
will run either continuously or periodically depending on
conditions.
In colder climates, an optional freeze sensor may be added
to protect against freeze conditions that may not be sensed
by the standard sensors. Auxiliary freeze sensor protec-
tion acts similarly except with the temperature thresholds
determined by the switch. See your dealer for details.
Clean-up Cycle (optional)
When a pump or blower is turned on by a button press, a
clean-up cycle begins 30 minutes after the pump or blower
is turned off or times out. The pump and the ozone gen-
erator will run for 30 minutes or more, depending on the
system. On some systems, you can change this setting.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Balboa SpaTouch2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Balboa SpaTouch2 in the language / languages: English as an attachment in your email.

The manual is 2.12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info