ty checks and component inspection procedures. If a fault exists that could
compromise safety, then no electrical supply shall be connected to the cir-
cuit until it is satisfactorily dealt with. If the fault cannot be corrected
immediately but it is necessary to continue operation, an adequate tempo-
rary solution shall be used. This shall be reported to the owner of the
equipment so all parties are advised.
Initial safety checks shall include:
That capacitors are discharged: this shall be done in a safe manner to
avoid possibility of sparking;
That there no live electrical components and wiring are exposed while
charging, recovering or purging the system;
That there is continuity of earth bonding.
Repairs to sealed components
1) During repairs to sealed components, all electrical supplies shall be dis-
connected from the equipment being worked upon prior to any removal of
sealed covers, etc. If it
isabsolutely necessary to have an electrical supply to equipment during
servicing, then a permanently operating form of leak detection shall be
located at the most critical point to warn of a potentially hazardous situa-
tion.
2) Particular attention shall be paid to the following to ensure that by
working on electrical components, the casing is not altered in such a way
that the level of protection is aected. This shall include damage to cables,
excessive number of connections, terminals not made to original specica-
tion, damage to seals, incorrect tting of glands, etc.
Ensure that apparatus is mounted securely.
Ensure that seals or sealing materials have not degraded such that they no
longer serve the purpose of preventing the ingress of ammable atmo-
spheres. Replacement parts shall be in accordance with the manufactur-
er‘s specications.
NOTE: The use of silicon sealant may inhibit the eectiveness of some
types of leak detection equipment. Intrinsically safe components do not
have to be isolated prior to working on them.
Repair to intrinsically safe components
Do not apply any permanent inductive or capacitance loads to the circuit
without ensuring that this will not exceed the permissible voltage and
current permitted for the equipment in use.
Intrinsically safe components are the only types that can be worked on
while live in the
presence of a ammable atmosphere. The test apparatus shall be at the
correct rating.
35
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Azuro Inverter at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Azuro Inverter in the language / languages: English as an attachment in your email.

The manual is 1,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info