CAPI 2.0 and Euro-ISDN Messages
NT/MPRI – 7 Messages 92
0x3006 B3 protocol parameter not supported[#3006]
This message indicates that the driver does not provide the
protocol options required by the application.
0x3007 B protocol combination not supported[#3007]
This message indicates internal application errors. Protocol
conflicts have occurred, The B protocols used are not compati-
ble and may not be used together.
0x3008 NCPI not supported[#3008]
The B-channel protocols in use are not compatible.
0x3009 CIP value unknown[#3009]
The service requested by the application is not implemented in
the controller software.
0x300A Flags (signals) not supported (reserved bits)[#300A]
This message indicates internal application errors. The signals
(flags) requested by the application are not supported by CAPI.
0x300B Facility not supported[#300B]
The ISDN driver does not support the requested supplementa-
ry service. Please contact your software manufacturer for more
information.
0x300C Data length not supported by current protocol[#300C]
This message indicates internal application errors.
0x300D Reset procedure not supported by current protocol[#300D]
This message indicates internal application errors. Contact
your software manufacturer for more information about appli-
cations that conform to CAPI.
0x3301 Protocol error, layer 1 (broken line or B channel removed by
signaling protocol)[#3301]
No connection could be established between the terminal
equipment and /or the exchange. The call set-up failed at layer
1 of the ISDN protocol. No messages could be exchanged be-
tween the terminal equipment and the network terminator or
local switch. Possible causes include: cable not correctly con-
nected; cable connectors miswired or wrong sockets used; net-
work termination not correctly enabled or not connected cor-
rectly to the line; defective terminal equipment at the bus
blocking communication.
Number Messages/Explanations
ntmpri-e.book Seite 92 Donnerstag, 28. Februar 2002 11:26 11
93


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for AVM ISDN MultiProtocol Router for Windows 2000 ADSL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of AVM ISDN MultiProtocol Router for Windows 2000 ADSL in the language / languages: English as an attachment in your email.

The manual is 3,51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info