If the desired mounting situation requires the
exhaust silencer to be mounted vertically, the
condensation drain hole must be drilled, as shown in Fig.
14b, to avoid the build-up of condensation in the exhaust
silencer. If that is not possible, it is recommended to
install it sideways (see Fig.14a).
The outlet of the exhaust pipe must be installed
pointing downwards (Fig. 8), and in such a position that
would prevent the clogging or invasion of snow and dirt,
and also provide a free drain for any water that gets into
it.
When installing on a maritime vessel, the silencer
must be mounted using the bolt and nut provided, so it
will be in a fixed position.
Make longitudinal cuts (about 15mm) (see Fig. 11,
Fig. 13, Fig.15) on the ends of the metal hose to ensure
better sealing when connecting the heater pipe to the pipe
for discharge of exhaust gases through the board of the
vessel, but without going beyond the pipe to be covered.
A rubber bushing (sold seperatly) must be used if
exhaust pipe goes through plastic parts. For example, the
bumper of a vehicle (see Fig. 15).
The exhaust pipe needs additional insulation at every connection of the
metal hose. For example, use a heat-resistant tape or sealant to prevent any
leaks of exhaust gases at connection points.
Additional heat insulation must be installed at all places where the exhaust
pipe goes through the floor or the sidewall of the vehicle (Fig.16) to avoid an
unnecessary fire hazard.
Fig. 15 - Attachment of the exhaust pipe to the heater and usage of rubber bushing
Fig. 14a Condensate drain hole for
horizontal mounting
5mm drill bit
Silencer
Condensate
drain hole
Silencer
Condensate
drain hole
5mm
drill bit
Fig. 14b Condensate drain hole for
vertical mounting
Exhaust pipe
Bolt and nut for
fixation
Clamp
Clamp
Cut
Silencer
Exhaust pipe
Cut
Cut
Rubber bushing
Insulation
Plastic partition
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Autoterm Flow at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Autoterm Flow in the language / languages: English as an attachment in your email.

The manual is 5.3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Autoterm Flow

Autoterm Flow User Manual - German - 37 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info