Fig. 10 - Installation of the air intake pipe
1 Air intake pipe;
4 Gasket;
2 Flange of the air intake pipe;
5 Fastener assembly;
3 Hull of the vessel;
6 Clamp.
3.4 Installation of the exhaust pipe.
When installing the exhaust pipe, take into
consideration the high temperature (up to 500°С) of the
exhaust pipe when the heater is in operation. Cut the
exhaust pipe (flexible crinkled metal hose, maximum
length 2 meters) to the necessary length. It is advised to
use a two-layer exhaust pipe when installing the heater.
Attach the exhaust pipe (Fig.11) using clamps and install
it so that it is slightly inclined to the bottom, in the
direction of the exhaust. Install heat insulation on the
exhaust pipe to protect individual sections of the vessel
(wiring or other heat-sensitive objects).
Fig. 11 - Attachment of the metal pipe
to the heater
Install the exhaust pipe to avoid the possibility of repeated intake of exhaust
gases by the air intake pipe, and make sure that no exhaust gases enter the interior
or are drawn in by the fan through the cab heater radiator.
At the end of the exhaust pipe, a shield is installed, which is necessary for stable
operation at low heating modes (Fig.13).
In the absence of the shield, air will be blown back
into the exhaust pipe. This leads to increased heater
sooting and impairs heat capacity. Exhaust gases must be
expelled outside of the vehicle.
An airtight exhaust silencer is provided with the
heater. This means it can be mounted in small vessels
and confined spaces. When mounting the exhaust
silencer on the outside of the vehicle, a Ø5mm hole
needs to be drilled at the bottom of the silencer (see Fig.
14a).
Cut 15 mm
Shield
Heat insulation
Fig. 13 Exhaust pipe shield
Clamp
Heater
Metal exhaust
pipe
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Autoterm Flow at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Autoterm Flow in the language / languages: English as an attachment in your email.

The manual is 5.3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Autoterm Flow

Autoterm Flow User Manual - German - 37 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info