Pallas 7 english
Heating in-between seasons
If you heat the stove in between seasons, when the outside
temperatures are higher, the flue gases may not be able to
escape completely and this may lead to disturbances in the
chimney draught, especially if the temperatures are rising
suddenly. The stove has to be charged with less wood then
and the primary air has to be increased so that the wood
can burn down faster (with visible flames) and thus the
chimney draught can stabilize.
Chimney fire
A chimney fire may occur, due to sooting and deposits in the
chimney, if improper or humid fuel is used. In case of a
chimney fire close all air inlets on the fireplace/chimney
immediately and call the fire brigade. Please have an expert
inspect your chimney for cracks and air-tightness after the
burning out of the chimney.
4. THE MOST IMPORTANT SPARESOVERVIEW
Keramott
Description
Nr. drawing
Part number
Bottom Keramott left
1
712766
Bottom Keramott right
2
712767
Bottom Keramott centre
3
712760
Rear, Keramott
4+5
712761
lateral Keramott right
7
712763
lateral Kermott left
6
712762
Keramoot baffle plate
8
712764
Keramott wood retainer
9
712765
Other parts
Description
Nr. drawing
Part number
Pallas door glass
10
712759
Door Handle
11
715238
BA1 spring
12
715641
Stove lacquer
--
650002
Glass cleaner ½ litre
--
640070
Gaskets
Description
Nr. drawing
Part number
Flat gasket 8 x 2 mm
13
710096
Round gasket 6 mm (0,5 m)
14
710696
Round gasket 14 mm (2,1 m)
15
714223
Accessories
You can obtain floor plates of glass or steel, care products or the Heat Memory System for heat storage from your certified
dealer.
IMPORTANT: Have defective parts replaced by your certified dealer. This will guarantee that your stove functions
properly and safely.
The fireplae must not be amended.
Maintenance
To clean the glass, please use a specialized product such as Thermohit glass cleaner. Lacquered surfaces are to be
cleaned only with a cloth (may be damp). Special cleaning agents should also be used for stainless steel surfaces.
Only gaskets in good order ensure the proper function of your stove!
Cleaning
The stove, flue outlets and smoke pipes should be cleaned and inspected for deposits every year if necessary more often,
e.g. after the cleaning of the chimney. The chimney also has to be cleaned regularly by the chimneysweeper. Your
chimneysweeper will inform you of the necessary inspection intervals. An expert should inspect the stove annually.
order of Keramott installation acc. to numbering
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Austroflamm Pallas at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Austroflamm Pallas in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 1,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info