1. Important information for stove operators
The information in these user instructions is of a general nature. National and European standards,
local and building regulations, as well as fire marshal provisions, must be complied with.
These user instructions must be attentively read prior to setting up and using the wood stove, and
before any intervention in it. Keep the user instructions carefully stored and ensure that they are
always available next to or near the wood stove.
Compliance with the rules contained herein ensures personal and material safety, economical
operation and a long service life. The EN 14785 standard was taken into account for the planning and
design of the wood burner.
No components may be modified or replaced by other parts which are not original equipment
manufacturer parts, otherwise the guarantee coverage and usage approval shall be rendered null and
void.
Disconnect the power supply to the wood stove prior to any intervention.
Schematics and drawings delivered along with the stove only serve as demonstrative examples; the
manufacturer pursues a policy of continuous development and updating of the product and may
undertake changes at any time without prior notification.
All dimensions stated in these user instructions are in mm.
ATTENTION: Only authorized Austroflamm service partners are allowed to carry out initial
commissioning of the device.
Your heating device is not suited for use as a ladder or support stand.
Please note that the surfaces of the pellet stove heat up substantially during operation. Always wear
protective gloves when using the pellet stove. Inform children as to the danger and keep them away
from the fire chamber during operation.
You must not burn any kinds of waste or refuse in the pellet stove. You must only ever burn the
recommended pellets (see the section entitled 3. Fuel).
Placing non-heat-resistant objects on the heating device or in its vicinity is prohibited.
Do not place any laundry items on the stove to dry. Keep laundry racks or similar at a sufficient
distance from the heating device fire hazard!
It is prohibited to handle highly flammable and explosive substances in the same or adjacent rooms
when operating the heating device.
It must be ensured that adequate combustion air intake and safe exhaust of the fumes is provided for.
Therefore you should always check whether there is any blockage in the chimney, especially after a
lengthier operational interruption.
In the period between Autumn and Winter, i.e. when outside temperatures are quite high, a sudden
increase in temperature can lead to malfunctions in the chimney flue, which means that the heating gases
are not completely extracted. If this is the case, switch the pellet stove off.
The convection grid may never be closed, not even partially.
Venting devices which are operated in the same room or room cluster along with the fire chamber can
cause problems.
You must clean or maintain the pellet stove regularly (see the section entitled 6. Cleaning).
Repairs to your pellet stove may only be performed by specialists trained by the manufacturer.
Have parts replaced as necessary and depending on the condition. Check the electrical and
electronic elements regularly for damage, wear and tear.
Safety devices may not be bypassed.
You must only ever open the combustion chamber door in the “OFF” operating condition. Otherwise,
you must keep this door closed even when the stove is not operating.
If you use the wrong fuel or fuel that is damp, a chimney fire can occur due to deposits in the
chimney. Close all the air vents immediately and call the fire brigade. After the chimney has burned
out, have a specialist inspect it for cracks and tightness.
Pellet devices are only suitable for being the one device that is connected to a chimney.
Please note that the installation location must have at least one outside door/window or be directly
connected to a room that does have an outside door/window. You must not operate other fire
chambers and extractor hoods as interconnected airways with fire chambers.
65 english
2. First steps
It’s this easy to commission your pellet stove:
1. Remove the accessories from the pellet tank, fill it up completely with pellets and close the tank
cover.
2. Plug in the mains cable.
3. Set the rocker switch on the back of the pellet stove to I.
4. The Austroflamm logo is displayed on the control panel. After a few seconds, the display changes
to this view:
5. If you want, you can change the display language (the symbol indicates the icons on the
control panel that you have to tap or hold down):
 “language / Sprache”
6. Tap the bar for the pellet tank at the bottom left (“FILL UP”). Then state that the pellet tank is full.
7. Start the stove:

(keep pressed)
8. When you use your pellet stove for the first time, the pellet screw conveyor is completely empty.
This means that you must use the “Manual feed” function to fill the screw conveyor before putting
it into service.
Tap the screen (if it is still in idle mode) to leave idle mode. If the display is not currently in idle
mode, skip this step.
''Manual feed''
Activate manual feed by keeping the “Feed” symbol pressed. After keeping the symbol pressed
for 30 seconds, manual feed is deactivated again automatically. If 30 seconds was not enough to
fill the screw conveyor, hold the symbol again. Repeat the procedure until the first pellets start
dropping into the burner bowl (this can take up to five minutes).
9. After a few minutes, the pellets start burning.
englisch
67


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Austroflamm Ben at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Austroflamm Ben in the language / languages: English, German, French as an attachment in your email.

The manual is 5,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Austroflamm Ben

Austroflamm Ben User Manual - Dutch - 23 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info