Id.Nr.: 123158-19
FUNCTION
The domestic water stored in the enamelled internal boiler is heated by the electrical heating insert. The
user can pre-select the desired temperature via the adjustment knob. The heater automatically switches
on during the heating times specied by the locally responsible power utility and switches o again when
the desired tank water temperature has been reached. When the water temperature drops, e.g. due to wa-
ter being drawn o or natural cooling (kept as low as possible by the high-quality CFC-free PU-foam insu-
lation), then the heater switches on again until the pre-selected tank water temperature has been reached.
HOT WATER REQUIREMENT
The hot water consumption in a household depends on the number of persons, the sanitary equipment in
the home or apartment, the insulation, the piping and the individual habits of the consumer.
The following table provides a number of typical consumption values:
Hot water demand in
litres
Required storage water quantity in
litres
at 37 °C at 55 °C with 80 °C with 60 °C
Full bath 150 - 180 55 - 66 78 - 94
Shower 30 - 50 11 - 18 16 - 26
Washing hands 3 - 6 1 - 2 1,6 - 3,1
Hair wash (short hair) 6 - 12 3 - 4,4 4,2 - 6,3
Hair wash (long hair) 10 - 18 3,7 - 6,6 5,2 - 9,4
Use of bidet 12 - 15 4,4 - 5,5 6,3 - 7,8
Washing dishes
for 2 persons per day 16 10 14
for 3 persons per day 20 12,5 18
for 4 persons per day 24 15,2 21,5
House cleaning per bucket
of cleaning water 10 6,3 9
(A temperature of approx. 12 °C is assumed for the cold water being mixed to achieve the specied hot
water temperature.)
ENERGY SAVINGS
The high-quality environmentally-friendly CFC-free PU foam insulation and integrated temperature regu-
lation make our electric at storage tanks real energy savers. Low storage tank water temperatures are
especially economical. The continuously adjustable temperature should therefore only be set to the actual
hot water temperature required. This helps to save energy and reduces the rate of limescale formation in
the tank.
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Austria Email EKF series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Austria Email EKF series in the language / languages: English, German as an attachment in your email.

The manual is 0.7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info