800526
11
Zoom out
Zoom in
Previous page
1/28
Next page
11
5. Öffnen Sie die Wasserzuleitung und
drehen Sie das Absperrventil (20 c)
im Kaltwasseranschlussstück (20)
lang sam auf (Pos.I). Prüfen Sie alle
Verbindungen auf Dichtigkeit.
6. Öffnen und schließen Sie danach
mehrfach das zugehörige Warm -
wasser zapfventil bis keine Luft mehr
aus der Leitung austritt und der
Durchlauferhitzer luftfrei ist.
5. Open the water supply line to the unit
and slowly open the shut-off valve
(20c) in the cold water connection
piece (20) (Pos.I). Check all connec tions
for leaks.
6. Open and close the hot water tap until
no more air emerges from the pipe and
all air has been eliminated from the
water heater.
Bei Aufputzmontage sind die beiden ½“
Einschraubnippel (23) und die ½“ Dich-
tungen mit den ½“ Überwurfmuttern
des Warmwasser- (1) und Kaltwasser-
anschlussstückes (20) zu verschrau-
ben. Die beiden ½“ Blindkappen der
seitlichen Abgänge des Warm- und
Kaltwasseranschlussstückes sind zu
demontieren und mit dem offenen Ende
der Einschraubnippel zu ver schrau ben. Die
Warm- und Kaltwasser anschlussstücke
sind dann mit den 3/8“ Dichtungen an
die 3/8“ Überwurfmutter des Gerätes und
Auslaufrohres zu verschrauben.
Bei Aufputzmontage ist es sinnvoll,
das Gerät mittels der mitgelieferten
Distanzhülsen gemäß nebenstehender
Zeichnung auf Abstand zu montieren.
Dabei ist zu beachten, dass auch die bei-
den Befestigungsbohrungen im unteren
Rohranschlussbereich benutzt werden.
Die Bördelseite der Rohre sind mit ½“
Überwurfmuttern und ½“ Dichtungen
an die seitlichen ½“ Abgänge des
Warm- und Kaltwasseranschlussstückes
zu schrauben. Abschließend sind die
Ausbrüche für die Rohre in der Haube mit
einem stumpfen Gegenstand herauszu-
brechen.
Bei Aufputzmontage beachten:
Sieb in das Kaltwasseranschlussstück
einsetzen!
For direct connection, the two ½“ screw-
in nipples (23) and the ½“ seals must be
screwed into the ½“ union nuts of the
hot-water (1) and cold-water (20) con-
nectors. The two ½“ caps of the side
outlets of the hot-water and cold-water
connectors must be removed and screwed
onto the open end of the screw-in nipples.
The hot-water and cold-water connectors
must then be screwed into the 3/8“ union
nut of the appliance and delivery pipe,
together with the 3/8“ seals.
For direct connection, it is advisable to
mount the appliance at a distance as illus-
trated alongside, using the spacer sleeves
supplied. It should therefore be noted that
the two fixing holes near the lower pipe
connections are also used.
The flared end of the pipes must be
screwed into the ½“ side outlets of the
hot-water and cold-water connectors with
½“ union nuts and ½“ seals. The holes
required for the pipes must then be bro-
ken out of the housing with the aid of a
blunt implement.
In case of direct connection please
note: Put the strainer into the cold
water connection!
7. Installation 7. Installation
8. Aufputzmontage 8. Direct connection
(20 c)
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Austria Email DEX21 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Austria Email DEX21 in the language / languages: English, German as an attachment in your email.

The manual is 2.99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info