810507
40
Zoom out
Zoom in
Previous page
1/60
Next page
38
Scheme with thermostatic three-way valve, two three-way mixing valves and two
additional mixer circuits after connecting an additional module
2
,
1 – boiler, 2 – regulator, 3 – control panel of regulator, 4 - boiler temperature sensor, 6 -
central heating circuit pump, 7 - thermostatic three-way valve (for return water control), 8 -
circulation pump, 9 - outside temperature sensor, 10 - hydraulic annulus (no need to
balance pump flows), 11 - DHW temperature sensor, 12 - DHW circuit pump, 13 - mixer
servomotor 1, 14 - mixer circuit pump 1, 15 - safety thermostat providing underfloor
heating 55ºC (disconnects the power supply of the mixer pump after exceeding the
maximum temperature - thermostat no is part of the controller equipment), 16 - mixer
room thermostat 1, 17 - mixer temperature sensor 1, 18 - mixer servomotor 2, 19 - mixer
circuit pump 2, 20 - outdoor thermostat providing underfloor heating 55ºC, 21 - mixer
room thermostat 2, 22 - mixer temperature sensor 2, 23 - mixer servomotor 3, 24 - mixer
circuit pump 3, 25 - outdoor thermostat providing floor heating heating 55ºC, 26 - mixer
room thermostat 3, 27 - mixer temperature sensor 3, 28 - mixer servomotor 4, 29 - mixer
circuit pump 4, 30 - mixer room thermostat 4, 31 - mixer temperature sensor 4, 32 - mixer
expansion module, 33 - DHW tank
RECOMMENDED SETTINGS:
Parameter Set value MENU
Mixer operation 1 Floor on Service settings mixer 1 setting
Max. set temperature of mixer 1 50 °C Service settings mixer 1 setting
Operation according to weather –
mixers 1 - 4
On menu mixers 1-4 setting
Heating curve of mixer 1 0,2 – 0,6 Service settings mixer 1 setting
Mixer operation 2 Floor on Service settings mixer 2 setting
Max. set temperature of mixer 2 50 °C Service settings mixer 2 setting
Heating curve of mixer 2 0,2 – 0,6 Service settings mixer 2 setting
Mixer operation 3 Floor on Service settings mixer 3 setting
Max. set temperature of mixer 3 50 °C Service settings mixer 3 setting
Mixer operation 3 0,2 – 0,6 Service settings mixer 3 setting
Mixer operation 4 Central heating on Service settings mixer 4 setting
Max. set temperature of mixer 4 80 °C Service settings mixer 4 setting
Heating curve of mixer 4 0,8 – 1,4 Service settings mixer 4 setting
Operation according to weather off Service settings boiler’s setting
2
The hydraulic diagram shown does not replace the central heating project! It is only an example!
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATTACK Pellet 30 Automatic Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATTACK Pellet 30 Automatic Plus in the language / languages: English as an attachment in your email.

The manual is 0.97 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of ATTACK Pellet 30 Automatic Plus

ATTACK Pellet 30 Automatic Plus User Manual - German - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info