810507
16
Zoom out
Zoom in
Previous page
1/60
Next page
14
Boiler regulation with room thermostat
In this case, the boiler will be regulated by a room thermostat, which will be connected to
the contacts of the electronics terminal board. The control function according to the room
thermostat must be selected in the boiler electronics. The boiler will also take into account
the set boiler temperature. Instead of a room thermostat, another type of heating
requirement can be installed, such as e.g. boiler control via internet.
Boiler protection
Boiler is equipped with emergency thermostat. If the boiler temperature exceeds
110°C, boiler safely gets out of order. When the boiler temperature decreases, it is
possible to start the boiler again by using the reset button placed on the back panel.
Fuel refill
Fuel is added to the fuel tank, which can be purchased as an optional accessory to the
boiler. The principle is that refueling should take place before the supply of pellets in this
tank is consumed. In the electronics it is possible to set the function of checking the
amount of fuel in the tank. Based on this setting, it is possible to display the current
amount of pellets in the tank on the boiler display.
ATTENTION! Fuel container can be open only when fuel is being refilled,
eventually by cleaning. Container has to be closed during the boiler operation.
Ash removing
The ATTACK PELLET 30 AUTOMATIC Plus boiler is equipped with device for
automatic ash re-moving into the detachable box. It is necessary to check the box 2x per
season and to empty it, if necessary. The space of the bottom of the combustion chamber
must be cleaned after the end of the heating season. Stop the boiler for a short time, when
removing the ash container.
When emptying the box (see the picture):
1.Close inlet opening into the container by pulling the lever on the container rear side fully
to the left
2.Release lever catches on container sides
3.Detach container from inlet tube of door cover by pulling it to yourself
4.Remove the ash
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATTACK Pellet 30 Automatic Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATTACK Pellet 30 Automatic Plus in the language / languages: English as an attachment in your email.

The manual is 0.97 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of ATTACK Pellet 30 Automatic Plus

ATTACK Pellet 30 Automatic Plus User Manual - German - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info