810512
39
Zoom out
Zoom in
Previous page
1/48
Next page
39
(where possible) or calculated by algorithm of
regulation in winter.
CH TEMPERATURE
Current temperature measured by the delivery
probe.
CH RETURN TEMPERATURE
Current temperature measured by the return
probe.
MODULATION POWER
Percentage level of modulation power (ame
level).
CH WATER PRESSURE
Level of water pressure in the system (prime
circuit).
BOILER EXHAUST TEMPERATURE
Current temperature measured by ue probe.
POWER AV. 24 HOURS
Average equivalent power delivered in the last
24 hours, mediated in the hour (picture10). It is
a purely indicative data, it can not be used for
tax purpose or for real power measuring. The
measure unit is kWe (equivalent to kW) and
it is referred to a standard boiler (potentially
parameterized using HEATING SETTINGS
Menu in the item PARAM. GRAPHICS
POWER).
Note: The loss of power supply > 24h, as
well as the factory data reset, will cause the
resetting of recorded data.
POWER AV. 30 DAYS
Average equivalent power delivered in the last
30 days. See what is explained in Power Av.
24 Hours.
POWER AV. 12 MONTHS
Average equivalent power delivered in the last
12 months. See what is explained in Power Av.
24 Hours.
6.1.3 GENERAL
FIRMWARE VERSION
Firmware Version loaded in the device.
6.2 HOT WATER SETTINGS
It is possible to set up some Hot Water parameters: Set (it
can be modied also from Hot Water Home through knob
picture 10
39


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATTACK OT80 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATTACK OT80 in the language / languages: English as an attachment in your email.

The manual is 1.29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info