er. When mounting back, it is necessary to pay attention to seal the draught breaker with the boiler
body tightly. The function of draught breaker is described in a separate part. Under the exchanger
is the burning chamber with atmospheric burners. The bottom of the chamber is equipped by a
dish on stands to keep condensate. The burner set consists of burner tubes holder with accesso-
ries and of burning system. It is connected to the burning chamber in two points. Gas distributor
is made as a closed steel profile. On the burner board there are burner tubes. Above them there
is an ignition burner together with thermocouple (ionization electrode) and ignition electrode in
a separated holder. The ignition burner and burning level can be watched through a small hole
above the holder of burning system. This part is accessible after removing the front door. Behind
the door there is an electromagnetic combined valve positioned on the gas supply pipe, which is
one of the main functional parts of the boiler. This valve is set up by a producer to the optimal burn-
ing quality and there should be no manipulation with it. Due to this is the regulation screw painted.
Under the valve there is a holder on the gas distributor (EKO, PLQ, P) with a piezoelectric ignitor
used for starting the ignition burner. Above the valve near the upper edge of the front door there is
a covered electroinstallation board with all the electroinstallation. The boiler body is protected by
a protective coating. The external cover is treated by heat resistant dust paint.
ELECTRICAL FRONT PANEL OF THE EKO, PLQ, KLV, KLQ, E BOILERS
HV main switch
PR – operation mode switch (only PLQ, KLQ)
KT boiler thermostat (1–5)
KT – PRODIGY "E" boiler thermostat
ZD thermomanometer
ELECTRICAL FRONT PANEL OF THE EZ BOILERS
HV – main switch – switch of the tank (EZ)
TD unblock button (EZ)
KP adjustable boiler potentiometer
ZD combined thermomanometer






   






   
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATTACK KLQ at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATTACK KLQ in the language / languages: English as an attachment in your email.

The manual is 1.22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info