810499
43
Zoom out
Zoom in
Previous page
1/92
Next page
43
Prescribed dimensions of the chimney section 15-45:
20×20 cm min. height 7 m
20 cm min. height 8 m
15×15cm min. height 11 m
16 cm min. height 12 m
The prescribed values of the chimney cross section dimensions for boiler 80, 100:
Ø 25 cm min. height 9 m
Ø 30 cm min. height 7 m
25x25 cm min. height 8 m
The exact chimney dimension is defined by the STN 73 42 10. The prescribed chimney draught is
given in the Technical parameters.
Flue gas connection
The flue connection must lead into the chimney hole. If it is not possible to connect the boiler to
the chimney hole directly, then the appropriate extension should be as short as possible, of up
to 1 m length, without any additional heating area and it should ascend in direction to the
chimney. The flue connection must be mechanically tight (it should be mounted to the boiler
and tightly fixed by screws) and tight against the flue leakage. The flue connections must to lead
through the foreign dwelling or commercial premises. The internal diameter of the flue
connection must not taper in direction to the chimney. It is not suitable to use the elbow
connectors.
Boiler connection to the electricity mains
The boiler is connected to the electricity mains of 230V/ 50Hzby an electrical cord with plug. In
the case of need, the power supply cord of the M type must be replaced with an adequate one
by the service organization. The appliance must be placed in the way enabling to reach the
connection plug. The boiler must be connected to the 16A socket circuit by a circuit breaker
(following the STN EN 60 335-1 + A11:1997).
Choice and connection of the control and regulation components
The boiler is delivered with the basic regulation and control equipment. Connection of these
items is given on the scheme of connection. We recommend extending the boiler regulation for
the next regulation components for more comfortable and economical operation. Each pump in
the system must be controlled by an individual thermostat not to let the temperature of the
heating water decrease under 65 °C.
The electrical installation related to the additional boiler equipment has to be done by
a specialist and following the valid regulations.
Connection of the next components is solved by a project architect according to the specific
conditions of the heating system. The electrical installation related to the additional boiler
equipment has to be done by a specialist and following the valid regulations.
Warning: the heating system must be equipped with a safety valve against
overpressure.
43


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATTACK DPX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATTACK DPX in the language / languages: English as an attachment in your email.

The manual is 11.03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of ATTACK DPX

ATTACK DPX Additional guide - English - 21 pages

ATTACK DPX Additional guide - German - 21 pages

ATTACK DPX User Manual - German - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info