810499
37
Zoom out
Zoom in
Previous page
1/92
Next page
37
Option Submenu Indication
Information
Test of device O
2
scales
End of the test (+, –)
After pressing the „+“ button is the text „calibrate“
displayed
The calibration takes approx.600 seconds.
Automatic calibration is done only in the case that
the boiler did not burn for 48 hours and the
operating time of the sensor is higher than 200
hours. By the manual setting there must be no fire
in the boiler, nor theglowing rest of the fuel! If it is
not necessary to adjust the scale, press „ĸ“ and
the next step is displayed.
Note: For quick exit from menu press „+“ and „–“ at
once.
Flue gas fan
End of the test(+,–)
By pressing +
start the flue gas fan
By pressing – stop the flue gas fan
By pressingĸselect the next point of the test
Circuit pump
End of the test(+,–)
By pressing +
start the circuit pump
By pressing – stop the circuit pump
By pressingĸselect the next point of the test
Primary motor
End of the test(+,–)
By pressing +
open the primary air flap
By pressing – close the primary air flap
By pressing ĸ select the next point of the test
Secondary motor
End of the test (+,–)
By pressing + open the secondary air flap
By pressing – close the secondary air flap
By pressingĸselect the next point of the test
Illumination
End of the test (+,–)
By pressing + turn the text display illumination on
By pressing – turn the text display illumination off
By pressingĸselect the next point of the test
Indicator light 1
End of the test(+,–)
By pressing +
turn the
indicator light
1 on
By pressing – turn the indicator light1 off
By pressingĸselect the next point of the test
Indicator light 2
End of the test (+,–)
By pressing +
turn the
indicator light
2 on
By pressing – turn the indicator light2 off
By pressingĸselect the next point of the test
Indicator light 3
End of the test (+,–)
By pressing +
turn the
indicator light
3 on
By pressing – turn the indicator light3 off
By pressingĸselect the next point of the test
Safety test
Setting
END
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATTACK DPX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATTACK DPX in the language / languages: English as an attachment in your email.

The manual is 11.03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of ATTACK DPX

ATTACK DPX Additional guide - English - 21 pages

ATTACK DPX Additional guide - German - 21 pages

ATTACK DPX User Manual - German - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info