25. Cleaning of the boilers and ash removal
The burner and the boiler must be cleaned regularly and thoroughly once every 1 to 30 days de-
pending on the quality of pellets and the output setting. Fly-ash and dirt accumulated in the combustion
chamber of the burner and boiler considerably reduce the service life and output. Do the regular clean-
ing of the boiler in such a way that you rst let the burner burn out (turn off the burner switch /20/).
Open the cleaning door, remove the front stainless-steel screen and clean the combustion chamber of
the burner, incl. the air openings in the chamber with the provided poker. If the combustion chamber of
the burner is heavily soiled, remove it for cleaning. Further, remove the decelerators from the tube plates
located in the top part of the combustion chamber and clean them with the provided brush. During this
cleaning return the front stainless-steel screen back to the boiler, but the other way round to make it
prevent large quantities of dust from falling out of the boiler during the cleaning. Also, do not forget
to clean the back smoke channel and scrape the walls of the combustion chamber of the boiler with the
provided poker or brush. Finally, remove the ash pan and dispose of the ash while observing all the fire
measures. The interval of the cleaning and ash removal depends on the fuel quality, heating intensity,
chimney draught and other circumstances. Put everything in the original condition after the cleaning.
At least once a year remove the burner and clean it completely. See the manual of the burner.
Removable combustion chamber of the bur-
ner with air supply openings - must be clea-
ned regularly
Sample cleaning of the tube plate with the
front screen arranged the other way round
Sample cleaning of the smoke channel. It is
performed after cleaning of the tube plate in
the combustion chamber of the boiler
Large ash pan partly drawn out
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Atmos D25P at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Atmos D25P in the language / languages: English as an attachment in your email.

The manual is 1,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info