693622
5
Zoom out
Zoom in
Previous page
1/26
Next page
GB
www.atmos.cz
6 - GB
Operation Manual - GB
Layout of the instrument panel
1. Thermometer
2. Main switch 7. 6.3A fuse - T6, 3A/1500 - type H
3. Control thermostat (of the boiler) 8. Place for an electronic control unit (92x138 mm)
4. Pump thermostat 9. Automatic deashing switch
5. Safety thermostat 10. Burner switch
Description:
1. Thermometer - monitors the output temperature of the boiler water
2. Main switch - allows you to switch off the whole boiler if necessary (restart the pellet burner)
3. Control thermostat - control the operation of the pellet burner by the output temperature of the
boiler water
4. Pump thermostat - it is designed to switch the pump in the boiler circuit (set to a temperature of 70-80°C)
5. Irreversible safety thermostat - it serves as protection of the boiler from overheating in case of a
failure of the control thermostat or as an indicator of exceeding of the emergency temperature - after
exceeding of the emergency temperature it must be reset
7. Fuse (6.3 A) - protection of the electronic unit of the pellet burner
8. The place for an electronic control unit of the heating system can be tted with any control unit that match-
es the opening (92x138 cm), e.g. ACD01. The electric harness is already prepared for its power supply.
9. Automatic deashing switch - it is used to switch off deashing for the purpose of emptying of the
auxiliary ash pan and restart of automatic deashing. By turning the switch off and on you will ac-
tivate the deashing module in such a way that it will stop emitting the warning sound and start the
automatic deashing operation.
10. Burner switch - it is used to start the burner and to stop it (initiate the burn-down process) before
cleaning of the boiler.
ČERPADLO / PUMP
KOTLOVÝ / OPERATING
3
8
4
5
7
9
10
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Atmos D25P at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Atmos D25P in the language / languages: English as an attachment in your email.

The manual is 1,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info