810412
56
Zoom out
Zoom in
Previous page
1/66
Next page
EN
www.atmos.cz
56-EN
Operation and Maintenance Manual - EN
If you are not sure, proceed as follows:
- Check whether the worm conveyor is really working by plugging the conveyor connector directly
to a wall socket, if so
- Turn off and on the main switch of the boiler and watch the lighting and flashing symbols on the
display of the electronic unit. Each start over a particular symbol on the display means that the
element or function is in operation or should be.
Each symbol on the display characterizes one element or function of the burner.
- Indicates operation of the external conveyor
-
Indicates connected control thermostat of the boiler
- Indicates connected ignition spiral 1
- Indicates connected ignition spiral 2
- Indicates the fan running at the starting or
operation speed
- Indicates connected reserve output R (bottom *)
- Indicates connected reserve output R2 (top *)
- Indicates that the photocell sees the flame
- If an error message related to the damage of a particular part on the burner appears immediately,
you should call the customer service to replace the damaged part
- If no error message appears, you must watch and compare the function of individual elements in
the burner by checking which symbol on the display is flashing or lighting up. This way you can
easily locate a possible defect within the burner (faulty part).
- If the burner or boiler is not energized, check the supply cable of the boiler or the cable between
the burner and the boiler
CAUTION - BEFORE OPERNING THE COVER TURN OFF THE MAIN SWITCH!
Checks of live parts may only be performed by a qualified person in accordance with
valid standards and laws.
Inspection procedure of the inner electric installation of the burner and boiler:
- Check whether the burner is energized
- Check whether the start signal is being sent to the burner - the control and safety thermostat
is connected - L2 - the symbol on the display is lit
- Check whether the supply phase - L1 - is flowing to the burner
- Check the fuses in the electronic board for the fan, conveyor and ignition spirals
- Check the terminal board for released contact
-
Check whether the ignition spiral at the start ignites (heats up) when the or symbol lights up
- Check the connection of the ignition spiral (supply wires)
- Check the connector of the supply cable of the burner for wrong connection - whether phase L1
(supply phase) is not interchanged with L2 (controlled phase) or reserve R, R2
56


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Atmos A85 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Atmos A85 in the language / languages: English as an attachment in your email.

The manual is 2.45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Atmos A85

Atmos A85 User Manual - German - 60 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info