Operation and Maintenance Manual - EN
Recommended approximate setting of the burner with the use of DRA50 – 1.7, 2.5, 4 and 5 m
conveyors, for individual output values and pellets with the diameter of 6 mm and conveyor
angle of 45°:
Boiler
output
Parameter
T1
Parameter
T4
Parameter
T6
Parameter
S3
Opening of the air
flap on the burner fan
of a boiler
with
an exhaust fan
Opening of the air
flap on the burner
fan of a boiler
without
an exhaust fan
28 - 32 kW 60 s 3 s 17 s 45 % 25 mm 1/3 (18 mm)
Recommended approximate setting of the burner with the use of DRA25 1,3 m and DRA25 1,7 m
m conveyors , for individual output values and pellets with the diameter of 6 mm and conveyor
angle of 65° (compact pellet tanks AZPD and AZPU):
Boiler
output
Parameter
T1
Parameter
T4
Parameter
T6
Parameter
S3
Opening of the air
flap on the burner fan
of a boiler
with
an exhaust fan
Opening of the air
flap on the burner
fan of a boiler
without
an exhaust fan
28 - 32 kW 85 s 5 s 10 s 45 % 25 mm 1/2 (25 mm)
INFO – Minimum length of hose between the burner and the conveyor must be
bigger than 20 cm. Maximum hose length should not be more than 1 m.
• Parameter S1Allowed number of attempts for ignition with fuel supply… (2)
If parameter S1 is set to 4, the fuel will always be ignited with both the ignition elements at
the same time (Z1 + Z2) in 2 attempts for ignition with fuel supply.
CAUTION - Always after the last attempt for ignition with fuel supply given by parameter
S1, an attempt for ignition without fuel supply will follow to test the equipment. If the fuel
is not ignited after this attempt, the system will be put out of operation and the ALARM
START error message will appear.
• Parameter S2 - fan speed at the START …(1 %) - do not change
CAUTION - 1 % = 700 rpm. If S2 = 0, the fan is off at the start.
• Parameter S3 – Fan speed during normal RUN …(100 %)
In normal circumstances we do not recommend you to reduce the fan speed as it influences
cooling and cleaning of inner parts of the burner. Only use the air flap to set the air quantity.
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Atmos A45SPT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Atmos A45SPT in the language / languages: English as an attachment in your email.

The manual is 6.79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info