1. General information
WA R N I N G - Before starting the burner you must get thoroughly acquainted with all provisions
of this manual. The manufacturer is not liable for damages caused by operation, maintenance
or wrong setting of the power of the burner that will cause heat overloading of the burner.
Introduction
This manual is intended for all users and contains information necessary for the installation,
start-up, maintenance and safe operation of the burner.
We recommend you to pay great attention to the safety regulations. Interventions that require
removal of some parts should be carried out carefully by qualified authorized experts. Repairs and
settings that are not described in the manual should not be carried out at all.
Application
The burner is designed for ATMOS DC18SP, DC25SP, DC30SPX, DC32SP, C18SP, C25SP,
AC25SP, AC32SP special boilers.
Technical specifications
Name: ATMOS A25
Prescribed fuel: high-quality (white) wooden pellets with the diameter of 6 to 8 mm, length of 5 to
25 mm and calorific value of 16 - 19 MJ.kg-1
Nominal heat input of the burner: 24 kW
Minimum heat input of the burner: 5 kW
Maximum heat input of the burner: 30 kW
Maximum heating surface of the boiler that the burner may be installed in: 3 m2
Fuel bin: not part of the delivery
Fuel feeding: with an external worm conveyor - not part of the delivery
Burner control: with an
AC07X
electronic control unit that controls the operation of the external
conveyor, two ignition spirals and the fan in accordance with requirements of the boiler and the
heating system. The electronic system is protected with the safety thermostat of the boiler, safety
thermostat at the pellet supply to the burner, the fan speed transducer and the flame sensing photocell.
The operation of the burner is indicated on the electronic control display.
Power supply: 230 V / 50 Hz
Maximum power input at the start with one ignition element: 522 W - normal setting
Maximum power input at the start with two ignition elements: 1042 W - special functions
Average power input at the nominal heat input operation: 42 W
Average power input at the minimum heat input operation: 22 W
Average heat input in the standby mode: 3.3 W
Prescribed fuse protection of the burner with the boiler: 6.3 A
Acoustic pressure level (noisiness): 54 dB
Burner weight: 17 kg
Burner dimensions, WxHxD: 25 x 47 x 55 cm
Minimum dimensions of the combustion chamber: diameter / width = 400 mm, length / depth = 400 mm
Minimum ashpan space of the boiler: must correspond to operation at the nominal output for at
least one week (min. 2 l)
Minimum vacuum in the combustion chamber of the boiler: 2 Pa
Min. protection against inadvertent opening of the boiler chamber (door): with a safety screw
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Atmos A25SP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Atmos A25SP in the language / languages: English as an attachment in your email.

The manual is 4.12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info