Never use the machine with a power supply cable of over
10 m in length. Longer power supply cables will cause a
drop in voltage. The motor will not be able to provide its
maximum performance and the operation of the machine
will be impaired.
17
Plugs and coupler outlets on connection cables must be
made of rubber, plasticised PVC or other thermoplastic
material of same mechanical stability or be covered with
this material.
The connector of the connection cable must be splash-
proof.
When running the connection line observe that it does
not interfere, is not squeezed, bended and the plug
connection does not get wet.
Wind off completely the cable when using a cable drum.
Do not use the cable for purposes for which it is not
meant. Protect the cable against heat, oil and sharp
edges. Do not use the cable to pull the plug from the
socket.
Regularly check the extension cables and replace them
if they are damaged.
Do not use any defective connection cables.
When working outdoors, only use extension cables
especially approved and appropriately labelled for
outdoor use.
Do not set up any provisional electrical connections.
Never bypass protective devices or deactivate them.
The electrical connection or repairs to electrical parts
of the machine must be carried out by a certified
electrician or one of our customer service points. Local
regulations – especially regarding protective measures
– must be observed.
Repairs to other parts of the machine must be carried
out by the manufacturer or one of his customer service
points.
Use only original spare parts. Accidents can arise for
the user through the use of other spare parts. The
manufacturer is not liable for any damage or injury
resulting from such action.
T
T
r
r
a
a
n
n
s
s
p
p
o
o
r
r
t
t
I
I
n
n
s
s
t
t
r
r
u
u
c
c
t
t
i
i
o
o
n
n
s
s
Move the splitting
blade right down every
time before the machine
is transported.
To transport the
machine, grasp the
handle and tilt the log
splitter slightly towards
you. The log splitter can
be easily transported in
this position.
Make sure that the oil
tank cap is securely
tightened to prevent oil from leaking during transport.
P
P
o
o
s
s
i
i
t
t
i
i
o
o
n
n
i
i
n
n
g
g
Place chocks under the wheels to prevent the machine
rolling during operation.
Ensure that the working area meets the following conditions:
no danger of slipping
level
free of obstacles
sufficiently well lit
Do not operate the machine in the direct vicinity of
gas or petrol pipes or containers, or any other easily
inflammable materials.
S
S
t
t
a
a
r
r
t
t
-
-
u
u
p
p
Check that the machine is completely and correctly
assembled.
Before using the log splitter, make sure each time that
there are no faulty connections (tears, cuts, etc.)
Do not use defective power supply cables.
there are no damages at the machine
all screws are tight
check the hydraulic system for any possible leaks
the oil level
Venting: Vent the hydraulic system before putting the
log splitter into operation.
¾ Unscrew venting cap by several turns so that air may
escape from the oil tank.
¾ Leave the cap open during operation.
¾ Close the venting cap before moving the log splitter,
as otherwise oil will leak at this point.
L If the hydraulic
system is not vented,
the trapped air will
damage the seals and
cause permanent
damage to the log
splitter.
Oil tank cap
5
4
L Mains connection
Transport belt
Compare the voltage given on the machine model plate
e.g. 230 V with the mains voltage and connect the
machine to the relevant and properly earthed plug.
Only use connection cables with sufficient cross-
sections.
Connect the machine via a 30 mA fault current safety
switch.
L Fuse protection
230 V ~ Î 16 A time-lag
400 V 3~ Î 16 A
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Atika ASP 6-1050 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Atika ASP 6-1050 in the language / languages: English, German, Dutch, Danish, French, Polish, Swedish as an attachment in your email.

The manual is 3,69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info