71192
38
Zoom out
Zoom in
Previous page
1/48
Next page
38
Connecting to the water supply
Inlet
Water pressure: 1–10 bar (flow pressure)
The appliance can be connected to cold and hot water, maximum
temperature 65 °C.
The site must provide a regulating tap with G 3/4” outlet.
The appliance must be connected with the plastic pressure hose sup-
plied (with filter, in accordance with EN61770, 10 bar.)
Installation of an IRG filter is recommended as part of the house’s
water system.
After the regulating tap is opened, no water may leak out of the con-
nection fittings.
If connecting to the hot water system, the threaded joints must be
checked a few minutes after the machine is first used and tightened
if necessary. (Be careful not to overwind the threaded joints.)
Drainage
The flexible drain hose with an inner diameter of 22 mm is to be laid
with no kinks.
The appliance can also be installed above the level of the sink spigot.
A return inhibitor is integrated into the machine’s drainage and
therefore connection fittings with non-return valves are not neces-
sary.
The preferred connection is via the spigot of the sink outlet in the
unit next to the machine.
The highest point of the drain hose is not to be more than 500 mm
above the floor of the appliance.
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATAG VA 5511 AT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATAG VA 5511 AT in the language / languages: English as an attachment in your email.

The manual is 1,2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of ATAG VA 5511 AT

ATAG VA 5511 AT User Manual - German - 44 pages

ATAG VA 5511 AT User Manual - Dutch - 47 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info