132
INSTALLATION
Ensure that the connection cables hang freely. If there is a drawer
underneath the hob, make sure that the contents do not project above
the edge of the drawer and interfere with the ventilation.
Installation of the induction hob above a combimicrowave oven, a 90 cm
ATAG oven or an oven of a different brand
Saw out the ventilation opening(s), making sure that the total surface of the
holes is a minimum of 100 cm
2
. See the drawing, for example, showing
2 holes.
Fit a protective plate between the oven and the hob. The plate should be
at least 10 mm thick and heat-resistant (85 °C). The space between the
underside of the hob and the protective plate must be at least 50 mm.
To protect the air flow, fit a protective panel - of the same material as the
protective plate - between the protective plate and the hob. Ventilation is
via the adjoining cupboards.
building in
e
r
t
No extra modifications for ventilation need be made where there is a fixed
panel.
Ventilationprotection
The electronics in the appliance require cooling. The cool air is sucked from
behind the cupboard and blown out at the front and at the bottom in the
front of the appliance. The hob can only operate if there is sufficient
circulation of fresh air. The appliance will switch off after a short time if
there is not enough circulation. See to it that the traverse lath does not
hinder the airflow.
Plane or saw the lath oblique if necessary.
Above a 60 cm oven of the ATAG brand
Recess height minimum 600 mm. Ventilation is via plinth and rear of
oven. Where there is a oven, a gap of at least 560 x 3 mm should be
made at the front. Cut out ventilation openings "A" + "B" (100 cm
2
).
Make an opening in the side wall "C" of the kitchen cupboard for
leading the connection cable through. The hob may only be combined
with ATAG ovens, not with combi-microwave ovens.
building in INSTALLATION
600
C
B
A
67


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATAG HI 6171 T at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATAG HI 6171 T in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 2,25 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info