installation island hood
The key dimensions are indicated on page 10.
Set the height of the telescopic pipe within
the allowable range.
It is advisable to suspend the hood with the
help of an assembly lift. If there is no lift
present, it is advisable to carry out the
mounting with more than one person.
Position the discharge and the electrical
connection in such a way that it will be easy
to hook up the hood.
marking
- Mark out the holes on the ceiling using
the template. Make sure that one of the
holes is at the front. Mark the drill hole for
the mounting plate too.
- Drill the holes (5 x 10 mm).
hanging telescopic pipe
- Fix the plugs and the studs to the
ceiling. Screw the studs 20 mm into the
plugs in the ceiling.
The locking hole should only have a plug
placed in it.
- Screw the washers and nuts onto the
bolts up to 6 mm under the ceiling.
- Put the top telescopic pipe over the studs.
Screw down the washers and the nuts.
Fasten the mounting plate to the ceiling
with a safety screw.
fastening glass plate
- Place the glass plate on the filter holder.
The arrow should point in the direction of
the control panel. Slide the filter holder
into the extractor hood.
- Screw the 5 nuts on loosely. Adjust the
glass plate and fasten it.
measuring
- Slide the lower telescopic pipe (with
motor and glass plate) over the already-
fitted upper telescopic pipe.
- Determine the length of the telescopic
pipe. Remember the minimum height
above the hob.
- Mark the drill holes and slide the two
sections apart again.
- Drill fixing holes (3,7 mm) at the side of the
upper telescopic pipe using the drill bit
supplied. Deburr the holes.
fitting extractor hood
- Fit the connecting cable and the
discharge hose from the inside. Make
sure that there are no kinks in the
discharge hose.
- Slide the hood over the telescopic pipe.
Secure it with the three screws.
installation wall hood
fitting extractor hood
- Slide the extractor hood onto the telescopic
pipe.
- NB: The upper telescopic pipe slides
between the motor housing and the lower
telescopic pipe (2 mm clearance).
- Adjust the telescopic pipe and fasten the
extractor hood with the washers and nuts
supplied.
- Place the glass plate on the filter holder.
The arrow should point in the direction of
the control panel. Slide the filter holder into
the extractor hood.
- Screw the 5 nuts on loosely. Adjust the
glass plate and secure it.
- Connect up the light cable.
- Attach the filter to the chain and secure the
filter by turning it clockwise.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATAG eg311l at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATAG eg311l in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info