128521
21
Zoom out
Zoom in
Previous page
1/30
Next page
10
installation wall hood
The key dimensions are indicated on page 10.
Set the height of the telescopic pipe within the
allowable range.
Position the discharge and the electrical
connection in such a way that it will be easy to
hook up the hood.
NB:
To prevent deformation, the tower should not
be placed on its flanged edge. Lay the tower on
its rear.
hanging the telescopic pipe
- Draw a centre line on the wall. Hold the
template supplied against the wall (centre
line to centre line). Slide the templates over
each other until you have reached the
correct height. Mark the drill holes.
- Drill the holes (10 mm). Insert plugs. Twist
two nuts in the opposite direction on the
ends of the studs and twist the studs
about 20 mm into the wall. Remove the
nuts.
- Secure the upper telescopic pipe.
- Attach the connecting cable and
discharge hose from the inside. Make
sure the connecting cable is not pinched
or folded.
A
Ø 10
Ø 10
196
195
62
187
20 mm
building-in dimensions
785-1000
425
305
420
530
900
196
62
195
177
ø125/150
196
900
530
785-1000
425
62
305
195
177
ø125/150
420
47°
700
1000
ø125/150
ø252
785-1000
425
ø305
785-1000
425
700
1000
47°
ø125/150
ø252
WG...L/WG...R
EG...L/EG...R
WG...P
EG...P
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for ATAG eg311l at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of ATAG eg311l in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info