5
DIGITAL THERMOSTAT OPERATION
DESCRIPTION
The sophisticated digital thermostat provides temperature read out, set point temperature, operating status of the
heater and any fault conditions.
TEMPERATURE DISPLAY
The temperature display indicates water temperature in the inlet of the heater. Therefore the pump must be
operating for an accurate pool or spa water temperature to be displayed.
Comfortable pool temperature is between 26˚C and 3C. Normal spa temperature is between 36˚C and 38˚C. To
select your desired temperature press the up or down button repeatedly until the desired temperature is reached.
To prevent rapid cycling of the heater, the thermostat has an inbuilt time delay which prevents the heater from
turning on for two minutes after the set point has been reached. If the time delay is activated, the symbol “L” will
be displayed on the LCD screen on the front of the heater. This is part of normal operation.
Should a fault condition occur, the heater will lock out and prevent further heating. A lock out condition is indicated
by the symbols F0 to F9. To reset a lock out condition, turn the power off for five seconds.
When the water temperature is heated to within 1 degree of the thermostat set point, the Viron burner will
modulate or turn down so that the set point is accurate maintained and not exceeded. This prevents waste of
energy typically associated with on/off burners. In addition, the set point is maintained very accurately, so the
when using your spa pool, you will notice very little variation in water temperature.
DISPLAY SYMBOL INDICATION
Under fault conditions the thermostat will display a set of alpha numeric symbols to indicate the status of the
heater. The meaning of each symbol and action to be taken are listed as follows:
SYMBOL MEANING ACTION
Temp Display Unit has power. No action.
F0 Heater locked off, thermistor If water temperature reads
wire disconnected or water greater than 0
C, phone for
at 0
C (freeze conditions). service.
F1 Thermostat reads greater Allow water to cool below 40
C ,
than 45
C. turn heater off then on again.
F2 Mechanical Hi Limit greater Allow water to cool below 30
C,
than 45
C. or 55
C turn heater off then on again.
F3 Thermistor fault Phone for Service
F4 N/A
F5 N/A
F6 Flue temperature safety device Phone for Service
locked out due to over temperature
F7 Condensate drain blocked Phone for Service
F8 Heat exchanger sensor fault Phone for Service
F9 Heat exchanger sensor too hot Phone for Service
Greater than 240degC
L Heater locked out on time No action. Heater will
delay for 2 minutes. Automatically reset after
time delay.
time delay.
Pump operating & sufficient No action.
water pressure to operate heater
Thermostat calling for heat. No action.
Electronic Flame Supervision
operating.
Burner Operating No Action
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Astralpool Viron eVo at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Astralpool Viron eVo in the language / languages: English as an attachment in your email.

The manual is 0,91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info