576954
7
Zoom out
Zoom in
Previous page
1/15
Next page
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL THE INSTRUCTIONS
CAUTION: Do not plug the power supply into a grounded outlet or do not switch the
pool cleaner “ON” if it is not fully immersed in water. Operating the cleaner out of water
will cause severe damage immediately and will result in loss of warranty.
Allow the cleaner to remain in the pool for 15 to 20 minutes following the end of its
cleaning cycle. This will allow the motors to cool adequately. Do not leave the cleaner
in the pool all the time. Always remember to turn the power supply “OFF” and unplug it
from the power outlet before removing the cleaner from the pool.
WARNING: The cleaner must not be used when people are in the water. For use
with swimming pool only
Safety Note
- The unit must be supplied through a residual current device (RCD) having a rated
residual operating current not exceeding 30 mA
- The connection to the branch circuit should be consistent with the local and national
wiring rules (electrical code).
- Mishandling of the unit can result in leakage of lubricants.
- If the supply cord is damaged, it must be replaced by the manufacturer’s service
agent or a qualified and trained person in order to avoid hazards.
Dear Customer,
Thank you for choosing our product to clean your pool. We hope that you will enjoy
using your new robot to maintain your swimming pool for years to come.
Before you begin to use your robot, please take a few minutes to carefully read these
operating instructions.
Again, thank you for choosing our product.
2
Components
Your new automatic pool cleaner contains:
- The robotic pool cleaner with its floating cable.
- The Power Supply (transformer).
- Caddy
Please read this manual completely before operating your pool cleaner
.
While the appearance of your cleaner and some of its components may differ from those
shown here, the function of the cleaner, operating procedures and maintenance
practices are the same.
WARNING: A Ground Fault Current Interrupter (GFCI-USA) or a Residual Current
Device (RCD-EUROPE) must be installed to protect your electric outlet and prevent
any possible electric shock.
This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for
their safety. Children should be supervised to ensure that they do not
play with the appliance.
SAVE THESE INSTRUCTIONS
Drive Track
Scrubbing Brush
Unit Body
Filter Top
Access
Handle
FIlter Lock
Release
Outlet Top
Side Plate
Handle Lock
Mechanism
Operating the pool cleaner
4
A
B
slot
key
C
D
Plugs Type I
To plug the cable (Fig A) into the socket on the power supply (Fig. B), please do the
following:
1.Prepare the plug as seen in (Fig. C) with the key and 3 outside slots exactly as shown.
2.Fit exactly the key and the slots from cable plug with the corresponding key and slots
from the power supply socket. (Fig. D)
3.Push the plug into the socket of the power supply all the way in.
4.Once the plug is in, rotate the plug to the right to lock it into place (Fig. E).
5.To remove the plug, first rotate the plug to the left to unlock it, then pull it out (Fig. F).
Socket (B)
Cable plug (A)
slot
key
Push and rotate
right to lock
E
Rotate left and
pull to unlock
F
cable
plug
cable
plug
power supply
socket
cable
plug
power supply
socket
5
6
External Timer Capability
This feature will enable the end user to
program the cleaning schedule through
an external timer (sold separately).
1
2 3
4
Grounding
The power supply must be connected to a grounded 3 conductor socket. The mains power supply
must be connected via a GFCI (ground fault circuit interrupter) or RCD (residual current device)
having a rated residual operating current not greater than 30mA.
Fuse
The fuse must be changed by an authorized service agent or trained and qualified person only.
For continued protection against risk of fire, replace only with the same type and rating of fuse.
Maintenance and safety
The cover should not be removed except by an authorized service agent or trained and qualified
person. No internal adjustment or component replacement can be carried out by the user. The
power cable must be disconnected before removing the cover.
If the power supply cord is damaged, it must be replaced by an authorized service agent or trained
and qualified person. Do not operate the supply if the cord is damaged.
Environmental conditions
The power supply is designed to work both indoors and outdoors. However, the unit should not be
operated in direct sunlight or be exposed to water. The power supply should not be operated in an
ambient temperature in excess of 40ºC.
Physical
Dimensions (W * D * H)
Weight
Electrical
Input rating
Output rating
Storage temperature
Operating temperature
Ingress protection
273mm * 242mm * 90mm
1.9 Kg
100-240V~, 50/60Hz, 210W
29V ,6.3A.
-10° C - 60° C
0° C - 45 ° C
IP54
1. Unit
2. Cable
3. Power supply
4. Power supply plug
5. External timer
6. Outlet
5
Operating the pool cleaner and power supply
a. Power LED
The blue LED flashes when the power supply is in standby mode and lights
continuously when the pool cleaner is operating.The power button switches
between ON and STANDBY
b. "POWER" button
The button switches between "ON" and "STANDBY".
IMPORTANT- After every cycle the pool cleaner will automatically go to "standby".
In case you want to turn the machine off during the working cycle, press the
"power" button once and the LED will start flashing, indicating that the machine
has stopped running.
IMPORTANT:
Please be sure to always keep your pool cleaner properly stored anywhere between 10 to 40 degrees Celsius (50 to 104 degrees Fahrenheit). This will keep the motors,
plastics and seals protected. Failure to comply will result in loss of warranty.
Robot can be used in water with temperatures ranging from 13°C to 35°C (55°F to 95°F). However, the recommended optimal temperature is between 22°C and 32°C (72°F
and 90°F)
Aquacontrol
Overlay
Aquacontrol
The Aquacontrol is a unique control panel which communicates
directly with the robot. This gives you the option to program the
time so that the pool can always be cleaned per your request.
If you prefer not to select this feature, the robot will work in default
mode and choose the time parameters for you.
7
6
4
3
1
2
CLICK!
CLICK!
8
7
Maintenance and adjustment - Cleaning the filter
5
It is recommended to clean the filter
after each working-cycle
Physical
Dimensions (W * D * H)
Weight
Electrical
Input rating
Output rating
Storage temperature
Operating temperature
Ingress protection
273mm * 242mm * 90mm
1.9 Kg
100-240V~, 50/60Hz, 210W
29V ,6.3A.
-10° C - 60° C
0° C - 45 ° C
IP54
Aquacontrol Power Supply Specifications
Maintenance and adjustment
Cleaning the pump propeller:
1) Take out the screws from the outlet top
2) Take out the outlet top and remove hair and other debris around propeller
outlet top
propeller
Screws
8
Adjusting the suction valve:
In order to increase suction power, the valves located underneath your cleaner can be
adjusted by pulling out the rim of the valve.
Before lowering the rim of the valve, make sure there is enough clearance and the unit
movements won’t be obstructed by any obstacles on the swimming pool floor or walls,
such as (drains, steps, etc.)
1) To pull out the rim rotate counterclockwise using a screwdriver (Fig. A)
2) To retract the rim rotate clockwise using a screwdriver (Fig. B)
A
B
CABLE CARE
The cable may become twisted after a period of time in use. To correct this condition,
simply lock the moveable handle on the top of the cleaner in the opposite diagonal
direction. The pool cleaner will now travel in the opposite direction while cleaning your
pool and the cable will uncoil. Check the cable periodically for external damage. If the
problem persists, use the E-Z Swivel device.
Place the robot on the ground and unplug the cable
from the transformer. With one hand, holding the E-Z
Swivel, walk away from the robot, pulling the cable to
its full length. The core will rotate inside the cover
and in this way will untangle the cable.
patent pending
Cable Assy
Core
Handle
Cover
E-Z SWIVEL
Shut off and unplug the power supply every time you remove the cleaner from the
water.
Clean the filter bag after every cycle.
Periodically straighten out the floating cable.
Replace worn brushes to ensure maximum cleaning performance
Save your cleaner's packaging for off-season storage or for shipping the unit to
your
dealer if service is required.
Leave your pool cleaner in the water for 15 to 20 minutes after every cleaning cycle.
Do not leave your cleaner in direct sunlight when not in use.
Never leave the power supply in direct sunlight and avoid leaving it in the rain.
Occasionally, you should rinse your cleaner in clean, fresh water. This will lengthen
the service life of the drive belts, drive tracks and scrubbing brushes.
Clean the propeller once a month
CLIMBING UNITS WITH FLOATING HANDLE ONLY
If your unit has floating handle, reverse the diagonal position after every cleaning
cycle to avoid tangling the cable.
Make sure that your pool cleaner positions itself properly on the wall. The machine
handle must rest parallel to the water line upon reaching the surface of the water.
IMPORTANT TIPS:
IMPORTANT:
Please be sure to always keep your pool cleaner properly stored anywhere between
10 to 40 degrees Celsius (50 to 104 degrees Fahrenheit). This will keep the motors,
plastics and seals protected. Failure to comply will result in loss of warranty.
Robot can be used in water with temperatures ranging from 13°C to 35°C (55°F to
95°F). However, the recommended optimal temperature is between 22°C and 32°C
(72°F and 90°F)
IMPORTANT:
The transformer cord can only be replaced with the aid of special tools,
normally available only to authorized dealers, distributors and service centers.
9
Maintenance and adjustment
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Astralpool RTX Robotic Pool Cleaner at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Astralpool RTX Robotic Pool Cleaner in the language / languages: English as an attachment in your email.

The manual is 7,68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info