Malfunction
Error code
Reason
Solution
Software control
exception
EE21
1.Compressor runs out of step
2. Wrong program
3. Impurity inside compressor causes
the unstable rotate speed
1. Check the main board or
change a new one
2. Enter correct program
Current detection circuit
failure
EE22
1. Voltage signal abnormal
2. Driver board is damaged
1. Check the main board or
change a new one
2. Change a new driver board
Compressor start failure
EE23
1. Main board is damaged
2. Compressor wiring error or poor
contact or unconnected
3. Liquid accumulation inside
4. Wrong phase connection for
compressor
1. Check the main board or
change a new one
2. Check the compressor
wiring according to the circuit
diagram
Check the compressor or
change a new one
Ambient Temperature
device failure on Driver
board
EE24
Ambient Temperature device failure
Change driver board or main
board
Compressor phase
failure
EE25
Compressors U, V, W are connected
to one phase or two phases.
Check the actual wiring
according to the circuit diagram
Four-way valve reversal
failure
EE26
1. Four-way valve reversal failure
2. Lack of refrigerant (no detect
when T3 or T5 malfunction)
1. Switch to Cooling mode to
check the 4-way valve if it has
been reversed correctly
2. Change a new 4-way valve
3. Fill with gas
EEPROM data read
malfunction
EE27
1. Wrong EEPROM data in the
program or failed input of EEPROM
data
2. Main board failure
1. Re-enter correct EEPROM
data
2. Change a new main board
The inter-chip
communication failure
on the main control
board
EE28
Main board failure
1. Turn off electricity supply
and restart it
2. Change a new main board
8. Troubleshooting
44


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Astralpool ELYO SMART NN at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Astralpool ELYO SMART NN in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 6,51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info