628507
105
Zoom out
Zoom in
Previous page
1/112
Next page
C
ALIBRATING
THE
EF1210
WITH
EFP
ANEL
C
ONTROL
S
OFTWARE
ASPI Digital - The Sound of DSP Technical Support: 404.892.3200 A-13
other Reference in step i.
v. Once the AEC Reference Inputs have been calibrated, click on the Next button
to proceed to Playback/Record calibration.
C
ALIBRATION
S
TEP
4: C
ALIBRATING
FOR
P
LAYBACK
AND
R
ECORD
For Calibration Step 4, the S
TEP
I
NDICATOR
will be lit in the fourth position. This
step calibrates the T
O
CODEC signal. No other calibration is necessary for Playback/
Record.
The T
O
CODEC signal may be adjusted to match the level required by your CODEC
(or other remote terminal equipment) input.
Caution!
If you skip this calibration step, you will compromise the
performance of the EF1210. The audio coming from or
going to the remote end may be too low, so if you turn up
the loudspeaker to compensate, the acoustic gain will be
affected.
Note.
You may skip this step if you are not using playback and record on
the EF1210.
Figure 26. Step 4: Calibrating for playback and record.
105


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aspi EF1210 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aspi EF1210 in the language / languages: English as an attachment in your email.

The manual is 0,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Aspi EF1210

Aspi EF1210 Additional guide - English - 3 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info