LENGTH OF 12 VAC/VDC HEATING CABLES (m)
(screened SYT1-type cable)
SB250 and SB2100
SB450, SB4100 and
SB4200
of wire
(mm)
Cross-sectional
area of wire
(mm
2
)
T R T+R T R T+R
0.6 0.3 75 75 30 40 40 20
0.9 0.6 170 170 80 85 85 40
1.4 1.5 400 400 200 190 190 95
1.8 2.5 600 600 300 300 300 160
2.3 4 1000 1000 500 500 500 250
T = Transmitter R = Receiver T+R = Complete detector (transmitter+receiver)
Note: If a single cable is used to supply power to several elements, the distances given should be
divided by the number of elements connected to the cable.
If several wires of the same cross-sectional area and polarity are placed in parallel, the
distances given should be multiplied by the number of wires.
Alarm and disqualification relay
Signal
Beam interuption
Alarm relay
Beam interuption
Alarm relay (NC)
Min
4 sec
Max 60 sec
Disqualification relay (NO) *
* This will free up the alarm relay when there are several alarm relays connected in series
(for example, different units on one pillar). If this option is not required, connect the alarm
and disqualification relays in series.
Connecting the tampering detection contact
Remove the PCB at the bottom of the module, connect the two wires and then replace the
PCB, sliding it in the two grooves until it can go no further, and taking care not to twist the
contact strip.
4. Channel selection
To avoid different detectors at the same site interfering with each other, they are equipped
with a choice of 4 frequencies (channels).
Each receiving and transmitting pair must be set to use the same channel. This is done
using DIP switches 3 and 4 at the top of the terminal block. The channel is validated by
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aritech SB 250 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aritech SB 250 in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 5,91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info