Installation
5
Copyright 1996 WARNING-Opto-Elektronik GmbH & Co Produktions KG
changes reserved
3 Installation
Installation procedure
1. For installation within moulded columns first of all prepare ground plate and moulded columns (see
3.4 installation with moulded columns)
2. For outdoor application install B-boards and heaters inside of the equipment (see 2.5
heaters)
3. Install the equipment at provided installation position (see 3.3 installation of the equipment)
4. Wire the equipment (see 3.2 wiring of the equipment)
5. Align transmitter and receiver (see 4 alignment)
6. Configuration of the system (see 5 putting into operation)
7. Check up system’s functioning (see 6 completion work)
3.1 VdS-Installation
The following has to be considered for the installation of a VdS-equipment:
1. The VdS-approval is only valid for indoor application
2. The alarm response time is to fix to 20 ms and not allowed to be altered
3. Never use a disqualification circuit when VdS is applied
4. Never use a heater for VdS application
5. Use only shielded cables with twisted pairs
6. The shielding of the supply line between transmitter and receiver are connected with
minus potential on both sides
7. The shielding of the supply line to the central control unit must be connected with ground
potential
8. The housings are to be connected with ground potential
9. For intended drilling work at moulded columns the devices have to be removed
completely
10. After fixing seal screws either with adhesive lead or lead wire
11. For installation of moulded columns they have to be equipped with cover contact
12. The jumpers at the transmitter and receiver are to be plugged in (pre-adjustment)
according to 5 putting into operation
13. Never apply any surface mirror at VdS-operation
3.2 Wiring of the equipment
Use only shielded cables with twisted pairs. The shields of the supply lines are to be connected as
described under VdS-application 3.2.1 wiring diagram.
Transmitter Receiver
1
2
3
4
5
6
7
+ / operating voltage
- / operating voltage
vacant (for shield, with – connected)
sabotage (only for single devices)
sabotage (only for single devices)
vacant (for closing resistance)
reference
1
2
4
5
6
7
8
9
10
3
11
+ / operating voltage
- / operating voltage
vacant (for shield, with - connected)
sabotage (only for single devices)
sabotage (only for single devices)
vacant (for closing resistance)
reference
NO
COM
vacant (for closing resistance)
technical interference
The sabotage contact of moulded columns is not brought out (the clamps 4 and 5 at receiver and
transmitter are not occupied).
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aritech DO560 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aritech DO560 in the language / languages: English as an attachment in your email.

The manual is 0,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info