557703
8
Zoom out
Zoom in
Previous page
1/24
Next page
Page 8
User Manual for CD72/95/15003
Beeeep
The alarm is now set.
System Armed
The current date and time automatically appears.
TUE 23 APR 07.40
A
RMING A SYSTEM WITH OPEN ZONES
When arming (switching on) the system, you may get the message
‘Open Zone(s)’
along with a list of
the zones in the premises that have not yet been closed. You should close these zones and then retry
arming the system. However, occasionally you may not be able to close an open zone because, for
example, a door lock or magnetic contact may be malfunctioning. You can exclude this open zone from
the system (called inhibiting a zone).
Only use this exclusion option when absolutely necessary as any inhibiting of zones will reduce the
security level of your system.
Although you can exclude an open zone when the tamper alarm has been triggered (identified by the
letter ‘T’ in front of the open zone listed), you will not be able to arm the system until the tamper alarm
has been rectified.
1. Go to the keypad. The current date and time appear on
the display. An example is shown.
TUE 23 APR 08.21
2. Press the key
0
and then enter your code. A ‘*’ appears in
the display for every key you press. Use the
0
key to
cancel an incorrect entry and to restart a new entry code.
Enter Code
0 + code
Enter Code ****
Arm Menu
3. Press the
Accept
key.
!
!!
!
Normal Set
4. Press the
Accept
key again.
!
!!
!
Normal Set
"
System Arming
The system has identified zones in the premises that are
not properly closed.
Open Zone(s)
It then proceeds to list the open zone(s). In this example,
zone 2 ‘Hall’ is open.
002 Hall
5. Press
"$
"$"$
"$
to exclude a zone from the system.
"
""
"
Inhibit Zone ___
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aritech CD15003 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aritech CD15003 in the language / languages: English as an attachment in your email.

The manual is 0,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info