702280
24
Zoom out
Zoom in
Previous page
1/28
Next page
20 ATS125x 4-Door DGP Installation Manual
3. For the 12 V model 3900 mA can be distributed. Higher current value drives the power supply into
current limit.
4. For the 24 V model 1600 mA can be distributed over 27.6 V contacts (Locks and Battery) and
1000 mA can be distributed over the 13.8 V contacts (auxiliary power incl. switched and the local
communications).
Fuses
F1: Battery 1 5 A, Fast 20x5
F5: Lock power 1 2 A, Fast 20x5
F2: Auxiliary power 1 A, Fast 20x5
F6: Lock power 2 2 A, Fast 20x5
F3: Local databus 1 800 mA, Fast 20x5
F7: Switched power 1A, Fast 20x5
F4: Local databus 2 800 mA, Fast 20x5
Mains
*
: Mains fuse 800 mA, Slow 20x5
* Mains fuse is part of the mains terminal block.
WARNING: Before removing the mains fuse, the mains power must be disconnected!
See “Mains power connection” on page 2.
Auxiliary current and battery capacity
Note: * This is only a reference to approval requirements. Please contact your local
sales office for more information about the valid certification.
Table 8: ATS1251 & ATS1253 auxiliary current and battery capacity (12 V models)
Battery type* 7.2 Ah 18 Ah 26 Ah
Approval grade* Discharge time (h) Charge time (h) Max. available auxiliary current (mA)
EN 1&2 12 72 450 1300 1800
EN 3&4 60 24 N/A 175 290
NF & A2P - 2 36 30 N/A 330 500
NF & A2P - 3 72 30 N/A 110 200
VdS - B 30 24 110 450 700
VdS - C 60 24 N/A 175 290
* Available battery capacities depend on the housing as well. Please refer to maximum battery
capacity in “Specifications” on page 19.
Table 9: ATS1252 & ATS1254 auxiliary current and battery capacity (24V models)
Battery type* 2 x 7.2 Ah 2 x 18 Ah 2 x 26 Ah
Approval grade* Discharge time (h) Charge time (h) Max. available auxiliary current (mA)
EN 1&2 12 72 500 1400 1800
EN 3&4 60 24 N/A 200 300
NF & A2P - 2 36 30 100 400 600
NF & A2P - 3 72 30 N/A 150 250
VdS - B 30 24 120 500 730
VdS - C 60 24 N/A 200 300
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aritech ATS1250 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aritech ATS1250 in the language / languages: English as an attachment in your email.

The manual is 0,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Aritech ATS1250

Aritech ATS1250 Additional guide - Dutch - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info