ATS125x 4-Door DGP Installation Manual 19
Specifications
General specifications ATS1251 ATS1252 ATS1253 ATS1254
End of line resistor Default: 4.7 k, 2%, 0.25 W
(Other: 10 k, 2%, 0.25 W; 2.2 k, 2%, 0.25 W)
Housing 480 x 464 x 160 mm 445 x 315 x 90 mm
PCB 202 x 218 x 48 mm
Colour Beige
Operating temperature 10 to +55°C
Humidity 95% noncondensing
IP protection grade IP30
Mains power specifications
Mains input voltage 230 V ~ ±10%, 50 Hz ±10%, 129 VA max.
Current consumption
at 230 V~
560 mA max.
Main board supply voltage
(J17)
30 VAC typical
Power supply specifications
Power supply voltage 13.8 ± 0.2 V 27.6 ± 0.2 V 13.8 ± 0.2 V 27.6 ± 0.2 V
Power supply current 4.0 A max.
@ 13.8 ± 0.2 V
1600 mA max.
@ 27.6 V
+ 1100 mA max.
@ 13.8 V
4.0 A max.
@ 13.8 ± 0.2 V
1600 mA max.
@ 27.6 V
+ 1100 mA max.
@ 13.8 V
Auxiliary power output 13.8 ± 0.2 V, 2 A max.
Note: Maximum permanent current to power devices external to the
control equipment in the absence of alarm conditions.
Battery power output 13.8 ± 0.2 V 27.6 ± 0.2 V 13.8 ± 0.2 V 27.6 ± 0.2 V
Battery type Lead acid rechargeable
Battery max. capacity 1 x 26 Ah nom. 2 x 26 Ah nom. 1 x 7.2 Ah nom.
or
1 x 18 Ah nom.
2 x 7.2 Ah nom.
Main board consumption 100 mA at 13.8 ± 0.2 V
Remaining current 3900 mA
@ 13.8 VDC
1600 mA max.
@ 27.6 VDC
+ 1000 mA max.
@ 13.8 VDC
3900 mA
@ 13.8 VDC
1600 mA max.
@ 27.6 VDC
+ 1000 mA max.
@ 13.8 VDC
Notes
1. Remaining current means all available current that can be used for the following: auxiliary power
(incl. switched), battery charge, lock power and local databus power. You can distribute the total
available current over the terminals as long as the maximum remaining current and fuse rating
for each output is respected.
2. The required battery current is dependant on the approval grade. See “Auxiliary current and
battery capacity” on page 20 for determining which current should be reserved for charging the
battery. Note that auxiliary power, lock power and local databus power is limited by the battery
current.
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aritech ATS1250 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aritech ATS1250 in the language / languages: English as an attachment in your email.

The manual is 0,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Aritech ATS1250

Aritech ATS1250 Additional guide - Dutch - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info