Connections
Table 2: ATS125x connections
Terminal block Wire Description
CON1 , Mains power connection
System earth (see details on page 5).
+, 2 x 12 V batteries, 7.2 Ah (24 V version) *
1 x 12 V battery, 7.2 Ah (12 V version)
CON2 +, Aux. power
+, Aux. power
S+, S ** External siren output
CON3 +, Lock 1 power
+, Lock 2 power
CON4 NO, COM, NC Door 1 relay
NO, COM, NC Door 2 relay
CON5 NO, COM, NC Door 3 relay
NO, COM, NC Door 4 relay
CON6 0V, D+, D System databus and panel tamper wiring (see page 7 for details).
T, C Tamper switch
CON7 1, 2, 3, 4 Zone 1-4 inputs
C Common
CON8 5, 6, 7, 8 Zone 5-8 inputs
C Common
CON9 12V, 0V, D+, D Local databus to connect RASs and DGPs (see page 7 for details).
CON10 12V, 0V, D+, D Local databus to connect RASs and DGPs (see page 7 for details).
* For 24 VDC models, always use two batteries in series.
** External siren output is a supervised output. Typical EOL resistor is 1 k.
Mains power connection
Use the mains terminal to connect the mains-supply. A fixed cable, or a flexible mains
lead to an earthed mains outlet, can be used. In case fixed wiring is used, insert a
dedicated circuit breaker in the power distribution network.
WARNING: Disconnect the mains power before opening the cabinet!
Disconnect the AC mains plug from the AC mains wall socket.
—or—
Disconnect the mains with the dedicated circuit breaker.
2 ATS125x 4-Door DGP Installation Manual
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aritech ATS1250 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aritech ATS1250 in the language / languages: English as an attachment in your email.

The manual is 0,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Aritech ATS1250

Aritech ATS1250 Additional guide - Dutch - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info