Smart Card Reader with Keypad
MOUNTING THE UNIT
1. Remove power to the control panel, or 4-door controller, as
applicable.
2. Remove the two front panel screws at the bottom of the RAS
(see figure ), and then remove the RAS back plate. Retain the
screws to secure the RAS later.
3. Position the RAS back plate (with the tamper spring at the top)
against the mounting surface to determine the locations of
mounting holes and for cabling access. (A reduced card reading
range may occur if mounted on a metal surface.)
4. Mount the back plate on a flat surface using four screws (the
hole nearest the tamper spring must have a screw in order for
the tamper switch to work correctly).
5. Terminate the cable, as required (see Wiring details below).
6. For on-line mode, set the BUS address (DIP switches 1 through
4). For on-line mode, set the TERM switch (DIP switch 5) as
required. For off-line mode, the TERM switch must be off (up).
See DIP switch settings for details.
7. Mount the RAS on the back plate by engaging the top, and then
lowering the RAS to be flat against the back plate. The rear
tamper switch must be sealed for the system to work correctly.
Ensure that the back plate tamper spring rests on the tamper
switch actuator (protruding from the resin in the back of the
RAS) when the RAS is in position.
8. Fix the RAS to the back plate using the two screws removed
earlier from the bottom of the RAS.
9. Apply power to the control panel, or the 4-door controller.
10. For on-line mode, use an LCD RAS on the BUS (or the system’s
management software) to program polling and set up the
required items for the new RAS. In particular, the ATS1197 RAS
must be programmed as a non-LCD RAS.
11. Check that the ATS1197 is communicating correctly and verify
that the tamper switch is working properly (i.e. “RAS Tamper” is
not showing on the LCD RAS).
IMPORTANT:
All power should be turned off to the control panel
before wiring the RAS.
LOCATION OF FEATURES (FIGURE )
1. Red/Green dual colour LED
2. Yellow LED
3. Red LED
4. Locking screws
CONNECTING CONTROL PANEL TO KEYPAD RAS
Refer to the ATS control panel installation guide for instructions.
TAMPER SWITCH
The ATS1197 tamper switch is closed when the unit is fitted on the
mounting plate. In operation, the LCD display will show “RAS
Tamper” when not closed.
RAS DIP SWITCH SETTINGS (FIGURE )
A row of DIP switches is located on the rear of the RAS (figure )
and is used for setting the RAS address and the bus termination
(TERM) condition. These settings are described in the following
sections.
1. RAS Address Set the RAS address using switches 1 to 4.
Switch in “UP” position is off, and switch in “DOWN” position is on.
2. TERM Switch Use switch 5 to set TERM to ‘ON’, if needed.
There must be no more than two TERM switches or links set to ‘ON’
for any bus. Refer to the control panel installation guide for details
about the use of TERM switches or links.
Note:
‘ON’ is indicated as black (down)
Example: RAS 2 = On, Off, Off, Off,
CONNECTIONS
Colour Application
Red +12 V nominal (8.5 to 14 VDC supply)
The RAS can be powered using the bus + and – power
from the control panel if the distance between the RAS
and the control panel does not exceed 100 m (328
feet). Otherwise the RAS can be powered by AUX
PWR from a DGP, or by an auxiliary power supply.
Black 0V (DC supply ground)
Green D0/D– /Clock, may be used for D0 (Wiegand data), D–
(RS485 data), Magnetic stripe clock. Normal operating
voltage 0 to +5 V (absolute maximum, +12 V).
White D1/D+ /Data, may be used for D1 (Wiegand data), D+
(RS485 data), magnetic stripe data. Normal operating
voltage 0 to +5 V (absolute maximum, +12 V).
The RAS is connected to the ATS panel via the RS485
data bus, up to 1.5 km from the control panel or the
four-door controller DGP. Use the 2-pair twisted,
shielded data cable (WCAT52/54)(recommended).
The shield of any bus cable must be connected to
system ground at one end only. The ATS111x RAS is
not provided with an Earth connection for this purpose.
If the bus is ‘daisy-chained’ to the RAS, ensure that
the shield of the cable is joined to provide continuity of
data cable shield.
Blue Buzzer/Beeper, may be used for offline buzzer control.
Wire open or +5 V to +12 V: buzzer off (Absolute
maximum, +14 V).
Wire grounded (0V): buzzer on.
Brown Application depends on selection of RAS menu option
2—Off-line LED control. See Programming.
Yellow
Application depends on selection of RAS menu option
2—Off-line LED control (see programming). When not
used for two wire LED control, yellow wire may be
used for
RTE input when online to ATS
connection to a simple push button for operation in
RTE Only mode
connection to a button for use in RTE + Arm/Disarm
mode.
Button should be connected to GND. See 10—RTE
(Egress) Control.
Violet
Open collector output, configurable as Door output,
Tamper output, or magnetic stripe data present. This is
a low current output and must not be used to directly
energize high current door openers. (Absolute
maximum, 14 V @ 50 mA)
Note: When using a door control relay, always place a
suppression diode (e.g. a 1N4001) across the relay
coil
STATUS LED INDICATIONS (FIGURE )
Connected to ATS control panel or access control panel
Green/Red
(disarm/arm)
Green when all areas assigned to the RAS’s
alarm group are disarmed or when screen-saver is
active. Flashing green when running on battery
(mains power off) or during unlock time when area
disarmed.
Red if all areas assigned to the RAS's alarm group
are armed. Flashing red during unlock time when
area armed.
LED off if at least one and less than all areas
assigned to the RAS's alarm group are armed
Yellow
(ready)
Active when all zones in areas assigned to the
RAS are normal (or active if RAS configured as
ATS1156)
Red
(alarm)
Flashing when any areas assigned to the RAS is in
alarm state.
Connected to a Wiegand or Magnetic Stripe interface
Green/Red
Green On when yellow wire is at 0V
Red On when brown wire is at 0V
Yellow On when yellow AND brown wire at 0V
LED off When yellow and brown wire are
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Aritech ATS1197 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Aritech ATS1197 in the language / languages: English as an attachment in your email.

The manual is 0,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info