655848
56
Zoom out
Zoom in
Previous page
1/68
Next page
56
GB
Replacing or resetting the thermostat
If the thermostat is deactivated, reset it and
establish the cause (short-circuit, faulty thermostat,
etc.).
CAUTION: Every thermostat is designed to be
reset a maximum of two or three times only!
Replacing the heating element
Check the Ohmic value of the heating element
and, if necessary, replace it. A null or an infinite
value indicates that the heating element must be
replaced.
Armoured range
The appliance must be emptied before the
armoured heating element may be replaced.
Steatite range PROfessional TECH steatite
range
It is not necessary to empty the appliance before
replacing the heating element. During a Technical
Assistance procedure for a steatite water heater,
it is absolutely necessary to replace the
plastic separator between the thermostat and
the heating element in the water heater as this
guarantees the correct operation of the appliance.
Picture 17 - Plastic separator / A: plastic separator
Replacing the electronic circuit
PROfessional TECH PTEC steatite range
Before performing any work, make sure you have
isolated the appliance from the electricity supply
network. The replacement of the electronic circuit
is a very simple process. After removing the plastic
protection:
Disconnect the storage cell (press-fit connector
on the storage cell).
Disconnect the 2 wires running from the
electronic circuit to the power supply terminal
board.
Disconnect the fast coupling connector with the
false movement protection device which links the
circuit to the boiler and the electrode.
Disconnect the electronic circuit from the
support (plastic material clips on the corners).
Replace the faulty circuit with a new one.
Repeat the procedure described above in the
reverse order.
Replace the battery.
PROfessional TECH steatite range - HPC
The storage cell is replaced by disconnecting the
press-fit connector and replacing the old storage
cell with a new rechargeable one, Ni-Mh 9 volt
150 mAh minimum.
56


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston STEA-serie at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston STEA-serie in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 3,33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info