ELECTRICAL WARNING:
The appliance must be earthed
The electrical installation must be in line with the current I.E.E. wiring regulations. A mains supply of 240 VAC 3 kW (13
amps) is required (Fig. 2)
Heat resisting cable, round 3 core 1.5 mm (to BS 6141 table 8) should be used to connect to the electrical supply through
either:
- a 13 amp socket to BS 1363; or
- a double pole fused isolating switch with a contact separation of 3 mm minimum on each pole.
Flexible cables are colour coded as follows:
Brown ........................................................ live
Blue ............................................................ neutral
Green and yellow ............................... earth
L
Safety relay 1
On/Off button
Temperature Adjustment
Temperature Visualization
Manual Reset
Functional relay 1
Heating element
User Interface
Sensor
NTC 1
NTC 1
CPU
NTC 2
NTC 2
Safety relay 2
N
E
127-240Vac
Input
R1
To enter into the terminal compartment unscrew the 2 screws on the cover.
(To access the screws, remove the decorative caps on the front control access panel).
It is mandatory, before installing the appliance, to perform an accurate control of the electrical system by verifying
compliance with current safety standards, which is adequate for the maximum power absorbed by the water heater
(refer to the data plate) and that the section of the cables for the electrical connection is suitable and complies with local
regulations. The manufacturer is not liable for damage caused by lack of grounding or anomalous power supply. Before
starting up the appliance, check that the power rating matches that given on the nameplate.
The use of multiplugs, extensions or adaptors is strictly prohibited.
It is strictly forbidden to use the piping from the plumbing, heating and gas systems for the appliance earthing con-
nection. If the appliance is supplied with a power supply cable, should the latter need replacing, use a cable featuring
the same characteristics . The power cord must be routed into the hole in the back of the appliance and connected to
the thermostat terminals (M Fig. 4).
The appliance must be grounded with a cable (yellow/green and longer than the phase cable) connected to the termi-
nals marked
(G Fig. 4).
Fig. 2
wiring diagram
On/Off button
Temperature Adjustment
Temperature Visualisation
Manual Reset
11


Need help? Post your question in this forum.

Forumrules
1

Forum

ariston-pro-1-eco

Reset search

  • How to adjust the temp as it keeps returning to full temp Submitted on 13-8-2022 at 11:02

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston Pro 1 Eco at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston Pro 1 Eco in the language / languages: English as an attachment in your email.

The manual is 1,62 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ariston Pro 1 Eco

Ariston Pro 1 Eco User Manual - Dutch - 16 pages

Ariston Pro 1 Eco User Manual - French - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info