Heat pump water heater – GENERAL INFORMATION
29
External unit
29
isuali
l
abel
Descri
ption
External unit 081
1
model
-
-
-
-
-
-
-
Level of protection
-
Type/quantity of refrigerant
-
Design pressure of the circuit
serial no.
2. TECHNICAL FEATURES
2.1 Operating principle
The heat pump water heater does not directly heat water using electrical energy, but makes a more rational use of the
latter to obtain the same result in a more efficient manner, namely by consuming approx. 2/3 less water.
The efficiency of a heat pump cycle is measured by the Coefficient of Performance (COP), i.e. the ratio between the
energy supplied to the appliance (in this case, the heat transferred to the water to be heated) and the electrical energy
used (by the compressor and the appliance’s auxiliary devices). The COP varies according to the type of heat pump
and to its relative conditions of operation.
For example, a COP value equal to 3 indicates that for every 1 kWh of electrical energy used, the heat pump supplies
3 kWh of heat to the medium to be heated, of which 2 kWh are extracted from the free source.
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston NUOS 200 SPLIT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston NUOS 200 SPLIT in the language / languages: English, Dutch, French, Italian as an attachment in your email.

The manual is 2,77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info