APPLIANCE PROTECTION DEVICES
Appliance shut-off conditions
The appliance is protected from malfunctions by means of
internal checks performed by the electronic P.C.B., which
stops the appliance from operating if necessary.
In the event of the appliance being shut off in this
manner, a code appears on the display which
refers to the type of shut-off and the reason
behind it.
Switch off the appliance. Make sure the external
electric switch is in the OFF position, shut off the
gas valve and contact a qualied technician.
Table summarising error codes
Error code Description
A1
Ignition fails - No ame detected
No ame after safety time(3 attempts)
- Open the valve and follow the activation procedure
- Check the ignition electrode
- Check the detection electrode
Press the ON/OFF to Reset
A2
Overheating (overheat thermostat/thermo
fuse) (95°C)
- A temperature higher than 95°C has been detected.
Check the water pressure
Press the ON/OFF to Reset
A3
Flue pipe blockage
- Verify the air intake/exaust fumes duct
Press the ON/OFF to Reset
A4
Flame lift (3 Times) during burning Press the ON/OFF to Reset
A6
Hot water temp. probe circuit open / short
circuit
Replace water outlet temperature sensor or repair
hardware circuit
A7
Cold water temp. probe circuit open / short
circuit
Replace water inlet temperature sensor or repair
hardware circuit
E6
Flame detected without gas ignition
Repair feedback needle or repair feedback
hardware circuit
E7
Fan error
Replace the fan or repair the fan drive and speed
detection hardware circuit
EE
Solar energy function fault protection The water inlet temperature exceeding 65°C
70
Parameter setting error protection
Error in parameter setting, please contact a qualied
technician.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston Next Evo X at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston Next Evo X in the language / languages: English as an attachment in your email.

The manual is 2,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info