591455
27
Zoom out
Zoom in
Previous page
1/88
Next page
12
sufficient capacity to guarantee an hourly exchange of air
equal to 3 ÷ 5 times the volume of the kitchen. Prolonged,
intensive use of the appliance may require extra ventilation,
e.g. an open window or a more efficient ventilation system
by increasing the extraction power of the electric fan if
installed. Liquid petroleum gas descends towards the floor
as it is heavier than air. Apertures in the outside walls in
rooms containing LPG cylinders should therefore be at floor
level, in order to allow any gas from leaks to be expelled.
Do not store LPG cylinders (even when empty) in basements/
rooms below ground level; it is advisable to keep only the
cylinder in use in the room and connected far from heat
sources which could raise its temperature to above 50°C.
Gas supply
Check that the appliance is set for the type of gas available
and then connect it to the mains gas piping or the gas
cylinder in compliance with the applicable norms in force.
This appliance is designed and set to work with the gas
indicated on the label situated on the actual hob. If the
gas supply is different from the type for which the
appliance has been set, replace the corresponding nozzles
(provided), following the instructions given in the paragraph
"Adaptation to different types of gas".
For trouble-free operation, suitable use of energy and a
longer life cycle for the appliance, make sure that the
supply pressure complies with the values indicated in table
1 "Burner and nozzle specifications", otherwise install a
special pressure regulator on the supply pipe in
compliance with current standards and regulations.
Connect in such a way that the appliance is subjected to
no strain whatsoever.
Either a rigid metal pipe with fittings (fig. 8-D) in compliance
with norms must be used for connecting to the nipple union
(threaded - cylindrical/conical ½"G fitting "F") situated at
the rear of the appliance (fig. 8), or a flexible steel pipe with
a continuous wall and fittings (fig. 8-C) in compliance with
norms, which must not exceed 2000 mm in length. Check
that the connecting pipe cannot come into contact with
moving parts which could damage or crush it. For installation
with a flexible rubber pipe, apply the special hose support
for liquid gas (fig. 8-A) or natural gas (fig. 8-B). The gasket
"G" (provided) must be utilised in every type of connection.
The two ends of the pipe must be fastened with the purpose
designed pipe collars "E", in compliance with the norms.
The flexible pipe should comply with the norms, and be
specific for the type of gas used. In addition:
it should be as short as possible, with a maximum length
of 1.5 metres;
it should not be bent or kinked;
it should not be in contact with the rear panel of the
appliance or in any case with parts which may reach a
temperature of 50°;
it should not pass through holes or slits used for dis-
charging the oven flue gases;
it should not come into contact with pointed parts or
sharp corners;
it should be easy to inspect along its entire length in
order to be able to check its condition;
it should be replaced before the date printed on the actual
pipe.
Important: A pressure regulator, in compliance with the
applicable norm in force, must be inserted when
connecting to a liquid gas supply (in a cylinder).
Upon completion of installation, check for leaks from the
gas circuit using a soapy solution (never use a flame).
Make sure that the natural gas pipe is adequate for a
sufficient supply to the appliance when all the burners are
lit.
Adapting to different types of gas (instructions for the hob)
To adapt the hob to a different type of gas from the factory-
set one (indicated on the rating plate at the top of the hood
or on the packaging), the burner nozzles should be replaced
as follows:
Remove the pan supports and the burners.
Unscrew the nozzles “A” (fig.9) using a 7 mm socket
wrench and replace them with the ones which have a
diameter suitable for the type of gas to be used, according
to the table 1 "burners and nozzles specifications).
• On completing the operation, replace the old rating label
with the one showing the new type of gas; the sticker is
available from our Service Centres.
A
fig.9
fig.8
fig.10
Note
Should the pressure of the gas used be different (or vary)
from the recommended pressure, it is necessary to fit a
suitable pressure regulator onto the inlet pipe in compliance
with the norms regarding "regulators for channelled gas".
INSTRUCTIONS FOR THE INSTALLER
Adjusting the primary air of the burners
The primary air of the burners does not need to be adjusted.
Adjusting the low flame
Turn the tap to the low flame position;
• Remove the knob and turn the adjusting screw, situated
to the right of the tap (fig. 10) until you obtain a regular
small flame, using a screwdriver (loosening the screw
increases the height of the flame, tightening decreases
it).
N.B.: In the case of liquid gas, the regulation screw
must be screwed in all the way.
Having obtained the low flame setting required and with
the burner lit, abruptly change the position of the knob
several times from minimum to maximum and vice versa
and check that the flame does not go out.
In appliances fitted with the safety device
(thermocouple), should the device fail to work with the
burners set to the low flame setting, increase the low
flame setting of the same on the adjusting screw.
Once the adjustment has been made, remount the seals
on the by-passes using sealing wax or similar.
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ariston CP 649 FT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ariston CP 649 FT in the language / languages: English, German, Dutch, French, Italian, Portuguese as an attachment in your email.

The manual is 2,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info