INSTALL THE CONNECTION PIPE
Connect the Outdoor Unit with Connecting Pipe: Aim the counter-bore of the connecting
pipe at the stop valve, and tighten the Taper nut with ngers. Then tighten the Taper nut
with a torque wrench.
When prolonging the piping, extra amount of refrigerant must be added so that the
operation and performance of the air conditioner will not be compromised
Note:
1. This table is for reference only.
2. The joints shall not be reused, unless after re-aring the pipe.
3. After installation, check the stop valve cover whether be xed effectively.
WIRING CONNECTION
1. Loosen the screws and remove E-parts cover from the unit.
2. Connect the cables respectively to the corresponding terminals of the
terminal board of the outdoor unit (see the wiring diagram), and if there
are signals connected to the plug, just conduct butt joint.
3. Ground wire: Remove the grounding screw out of the electric bracket,
cover the grounding wire end onto the grounding screw and screw it into
the grounding hole.
4. Fix the cable reliably with fasteners (Pressing board).
5. Put the E-parts cover back in its original place and fasten it with screws.
Insert a circuit breaker with sufcient power and observe the following
table:
WIRING DIAGRAM
The diagram are for reference only.
Please refer to the detailed wiring diagram
adhered on the unit which you purchased.
VACUUMING
Exclusive R32 refrigerant pump must be used in making R32 refrigerant vacuum.
Before working on the air conditioner, remove the cover of the stop valve (gas and liquid valves) and be sure to
retighten it afterward (to prevent the potential air leakage).
1. To prevent air leakage and spilling tighten all connecting nut of all are tubes.
2. Connect the stop valve, charge hose, manifold valve, and vacuum pump.
Stop valve Taper nut Connection
pipe
Liquid side pipe
Gas side pipe
Spanner
Variable speed
Connector
If there is a connector, connect it directly
Constant speed
To indoor unit
To indoor unit
To indoor unit
To indoor unit To power
To power
To power
To power
L
N
S
L
Lo
N
LN1 3
1 3 45
N(2)
N(2)
LN
S
Piping lenght Amount of refrigerant to be added Amount of refrigerant
for the unit
Not needed
<3M CC12000Btu 20 g/m 1 kg
CC18000Btu 40 g/m 2 kg
3-5M Not needed
5 - 15M CC12000Btu 16 g/m 1 kg
CC18000Btu 24 g/m 2 kg
Magnetothermic
switch power
14K - 16A
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Argo Hi-comfort Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Argo Hi-comfort Plus in the language / languages: English as an attachment in your email.

The manual is 3.06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Argo Hi-comfort Plus

Argo Hi-comfort Plus User Manual - Italian - 31 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info