DIMENSION DRAWING OF OUTDOOR UNIT INSTALLATION
INSTALLATION OF OUTDOOR UNIT
Space to the obstruction
Air out side
Air in side
10 cm above
200 cm above
30 cm above 50 cm above
50 cm above
Space to the obstruction
Space to the
obstruction
Air outlet
Left installation feet
H
W2
A
D
B
W1
Right installation feet
Air inlet
Outdoor unit size oh shape
W1(W2)*H*D (mm) A (mm) B (mm)
665(710)x420x280 430 280
600(710)x500x240 500 260
730(780)x545x285 540 280
709(761)x536x280 480 283
750(804)x550x285 480 283
800(860)x545x315 545 315
785(845)x555x300 546 316
825(880)x655x310 540 335
900(950)x700x360 632 352
970(1044)x805x395 675 410
940(1010)x1320x370 625 364
940(1008)x1366x401 610 388
Installation outdoor unit bolt
REFRIGERATING CONNECTIONS
Use equipment and connecting pipes suitable for R32 refrigerator.
Always write the additional refrigerant charge on the data label afxed to the unit outside.
MODELS 9000 12000 18000 24000
Min. - Max. pipe lenght with gas standard
charge (m) 3 - 7 3 - 7 3 - 7 3 - 7
Max. pipe lenght with gas additional charge (m) 20 20 25 25
Additional refrigerant charge (g/m) 15 15 25 25
Max. height between units (outdoor on top) (m) 10 10 15 15
Max. height between units (indoor on top) (m) 10 10 15 15
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Argo Hi-comfort Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Argo Hi-comfort Plus in the language / languages: English as an attachment in your email.

The manual is 3.06 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Argo Hi-comfort Plus

Argo Hi-comfort Plus User Manual - Italian - 31 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info