EG
1. Remove the cap.
2. Install a valve in order to discharge water from the circuit (in case of need).
3. Install the expansion vessel min. 18 litres (½” connection).
HOT WATER
TEMPERATURE
ADJUSTMENT
38°-65° C
HYDRAULIC CONNECTION BETWEEN EMIX TANK AND DOMESTIC WATER CIRCUIT
Connect the water to the tank. Install an expansion vessel of 18 litres minimum and service valves on the
connections of the water circuit in order to make installation and maintenance operations easier. The output of
the safety valve should be connected to a drain.
• Install a lter upstream the cold water circuit and a softener (or polyphosphate treatment system) to avoid
limestone.
Here below you can see the water connections and how to set the thermostatic mixing valve.
E
HOW TO INSTALL EXPANSION VESSEL
Expansion vessel installation is always warmly recommended in order to prevent hydraulic issues to Emix Tank
unit
(e.g. due to suddenly pressure change in the water inlet circuit) and, most of all, to counteract the pressure in-
creasing due to water heating.
F
Connect here the discharge
valve and the expansion
vessel
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Argo Emix at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Argo Emix in the language / languages: English as an attachment in your email.

The manual is 1,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Argo Emix

Argo Emix User Manual - English, German - 30 pages

Argo Emix User Manual - German - 29 pages

Argo Emix User Manual - French - 30 pages

Argo Emix User Manual - French - 29 pages

Argo Emix User Manual - Italian, Portuguese, Swedish, Spanish, Finnish - 30 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info