665483
4
Zoom out
Zoom in
Previous page
1/30
Next page
EG
4
3/4” water lter to be installed upstream of tap water connection, if not already present in the system.
Sensor of stratication (tank temperature).
ACCESSORIES SUPPLIED WITH THE UNIT
When connecting refrigerant tubing
•Keepalltubingrunsasshortaspossible(max. 10m), accordingly to the allowable distances from the outdoor unit (see
manual).
•Usetheflaremethodforconnectingtubing.
•Applyrefrigerantlubricanttothematchingsurfacesoftheflareanduniontubesbeforeconnectingthem;screwby
hand and then tighten the nut with a torque wrench for a leak-free connection.
•Checkcarefullyforleaksbeforestartingthetestrun.
•Insulatethetubeswithfoamedpolyethylene(min.thickness8mm)
When connecting hydraulic tubing
•Keepalltubingrunsasshortaspossible.
•Insulatethetubing.
•Checkcarefullyforleaksbeforestartingthetestrun.
When servicing
•TurnthepowerOFFatthemainpowerboardbeforeopeningtheunittocheckorrepairelectricalpartsandwiring.
•Cleanupthesiteafterthework,rememberingtocheckthatnometalscrapsorbitsofwiringhavebeenleftinsidethe
unit being serviced.
•Ventilatetheroomduringtheinstallationortestingtherefrigerationsystem;makesurethat,aftertheinstallation,no
gas leaks are present, because this could produce toxic gas and dangerous if in contact with flames or heat-sources.
•
We recommend this appliance to be installed properly by qualified installation technicians in accordance with the installation
instructions provided with the unit.
•Donotinstallthisappliancewheretherearefumesorflammablegases,orinanextremelyhumidspacesuchasagreen
house.
•Donotinstalltheunitwhereexcessivelyhighheat-generatingappliancesareplaced.
Do not install the unit where it could be wetted by drops of water (i.e. in laundries).
Do not install the unit in rooms with high humidity and subjected to high steam production (in the bathroom, for
example).
•Do not install the unit outside.
•Do not install the unit in rooms exposed to the risk of freezing.
IMPORTANT ! The room in which the product is installed must be equipped with floor drain sump, connected to
sewer system.
AVOID
•Directsunlight.
•Areaswhereleakageofflammablegasmaybeexpected.
•Locationswherelargeamountsofoilmistmayoccur(suchasinkitchenornearfactoryequipment)becauseoil
contamination can cause operation problems.
•Tomakeholesinareaswhereelectricalwiringorconduitsarelocated.
IMPORTANT !
In the absence of the precautions described above, THE MANUFACTURER shall not be held responsible for
any damage caused.
WARNING
INSTALLATION LOCATION
ELETRICAL REQUIREMENTS
Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown
on the nameplate.
All wiring must conform to the local electrical codes. Consult your dealer or a qualified electrician for details.
The unit must be properly grounded with a ground (or earth) wire or through the supply wiring.
Wiring must be done by a qualified electrician.
•Theprotectionsonthepoweroutputsrefertotheapplianceconnectedtothem.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Argo Emix Tank at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Argo Emix Tank in the language / languages: English, German, French, Italian, Portuguese, Swedish, Spanish, Finnish as an attachment in your email.

The manual is 4,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Argo Emix Tank

Argo Emix Tank User Manual - English - 29 pages

Argo Emix Tank User Manual - German - 29 pages

Argo Emix Tank User Manual - French - 29 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info