Question 10 What happens if my water becomes cloudy?
1. Check you pH level to ensure it is in the target range. If high, lower the pH using Arctic Pure Salt Water Bal-
ance.
2. Check/Test the water with a drop test kit for chlorine content. If the level is below 0.5ppm or there is no read-
ing the Spa Boy Output Electrode may be exhausted and require replacement. Check Cell Life Monitor on Arc-
tic Spas App or myarcticspa.com dashboard under “Settings/Spa Boy Status”, remaining Cell life is displayed
as a green colored battery. The green band on the battery will reduce in height as the Cell becomes depleted.
3. Check that the Salinity reading is within the desired range, 2000ppm and 2500ppm. If salinity reading is
below the range it can cause the Cell Life Monitor to display as Red, which implies the Spa Boy Salt Cell is
exhausted when it may not be.
4. Check your lters as they may require replacement.
Question 11 Should I use Best Defense or another scale remover? It is recommended that calcium be re-
moved from the water in advance, during the ll process with the aid of a pre-lter and when establishing initial
correct water chemistry, rather than adding a scale remover after the fact. Calcium readings below 150ppm
should be maintained.
Question 12 What is the impact of phosphates on the Spa Boy system? High levels of phosphates (above
250 ppb) may reduce the e󰀨ectiveness of sanitizer output.
Question 13 Can I use softened water with my Spa Boy system? Yes, you probably have a water softener
because your water is quite hard. Your water softener removes calcium from your water and helps you achieve
water with calcium content near the target range, between 50 - 150 ppm.
Question 14 Prior to draining spa water for rell purposes, should a system ush be carried out? Yes
you can, Arctic Pure ‘Fresh Start’. Use in accordance with the instructions on the container. Flushing the system
components and hoses is helpful when you get biolm and calcium build-up. It is good practice to do this at
least once a year.
Question 15 If I am going to have a very heavy bather load, is there a way to manually active the Spa
Boy System to generate additional sanitizer (Increase ORP Level)? Yes you can. Pressing the Boost But-
ton through the App or dashboard in myarcticspas.com will manually activate the Spa Boy System for 30 min-
utes. Boost button can be activated in such cases when you know you are going to have a heavy bather load.
CAUTION: Only press the Boost Button once.
When the Boost Button is pressed:
• The Lightning Bolt on the Boost Button will illuminate and then,
• The Spa Boy Generator will turn On and O󰀨 TWICE along with the Lightning Bolt, and then,
• The Boost function commences its 30-minute cycle. During this cycle the Lightning Bolt remains illuminated.
Pressing the Boost button more than once will cause the Boost function not to activate.
Understanding Spa Boy®
Owners Manual - Spa Boy®
9090
90


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Arctic Spas Mustang at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Arctic Spas Mustang in the language / languages: English as an attachment in your email.

The manual is 5,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info