E-6
The remote-control and trigger inputs
The REMOTE IN input can be used to pass RC5 codes to the DV139 if it is installed in a position (or
system) where infrared cannot be used. If this is required, please contact your dealer for further
information.
The TRIGGER IN input can be used to switch the DV139 in and out of stand-by. Connecting the
trigger output of your Arcam amplier (or other compatible device), will cause the DV139 to come
out of stand-by automatically when the amplier is switched on, returning to stand-by when the
amplier is switched off. Please see your amplier handbook for further information.
In normal use there is no need to make any connections to these inputs.
Inserting the batteries into the remote control
The remote control requires four ‘AAA’ batteries to operate. To insert the batteries into
the remote control, please follow the instructions in the side panel diagram:
Notes on inserting the remote control batteries
<
Incorrect use of batteries can result in hazards such as leakage and bursting.
<
Do not mix old and new batteries together.
<
Do not use different kinds of battery together—although they may look similar,
different batteries may have different voltages.
<
Ensure that the plus (+) and minus () ends of each battery match the
directions in the diagram on the right.
<
Remove batteries from equipment that is not going to be used for a month or
more.
<
When disposing of used batteries, please comply with government (or other)
regulations that apply in your country or area.
Using the remote control
Please keep in mind the following when using the remote control:
<
Ensure that there are no obstacles between the remote control and the remote
sensor on the DV139. The remote has a range of about 7 metres. (If the remote
sensor is obscured, the remote control input jack on the rear panel is available.
Please contact your dealer for further information.)
<
Remote operation may become unreliable if strong sunlight or uorescent light is
shining on the remote sensor of the DV139.
<
Replace the batteries when you notice a reduction in the operating range of the
remote control.
Connecting to a power supply
Mains lead
The appliance is normally supplied with a moulded mains plug already tted to the lead. Check that
the plug supplied with the unit ts your supply and that your mains supply voltage agrees with the
voltage setting (115V or 230V) indicated on the rear panel of the unit. If for any reason the plug needs
to be removed, it must be disposed of immediately and securely, as it is a potential shock hazard when
inserted into the mains socket.
If your mains supply voltage or mains plug is different, or you require a new lead, please consult your
Arcam dealer.
Plugging in
Push the plug (IEC line socket) of the power cable supplied with the unit into the socket (POWER INLET)
in the back of the unit. Make sure it is pushed in rmly.
Put the plug on the other end of the cable into your power supply socket and switch the socket on.
The remote control
input requires a mono
3.5mm jack, with the
tip active and the sleeve
grounded.
The remote control signals
must be in modulated RC5
format (at 36kHz), with a
voltage level of between
5V and 12V.
1. Open the battery
compartment by pressing
the button on the back of
the handset.
2. Insert four AAA batteries into
the battery compartment:
two with ‘+’ facing the top
of the handset, and two with
‘+’ facing the end cap, as in
the diagram.
3. Lower the end cap onto
the plastic locating plate in
the handset. This acts as
a hinge, and you can now
push the end cap rmly into
its locked position with a
click.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Arcam dv 139 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Arcam dv 139 in the language / languages: English as an attachment in your email.

The manual is 1,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info